background image

The Cube Technical Manual - Version 1, May 2014

2

3

Declaration

Waterlogic International Ltd

1.

 The installation, maintenance and sanitizing procedures must be carried out by persons trained by 

Waterlogic International or their approved distributors. Do not remove any panels or covers unless 
acceptable in this instruction.

2. 

When any abnormal case happens, firstly unplug the appliance.

3. 

This appliance is not intended for use by persons (including children) with reduced physical, sensory 

or mental capabilities, or lack of experience and knowledge, unless they have been given supervision 
or instruction concerning the use of the appliance by a person responsible for their safety.   

4. 

Children should be supervised to ensure that they do not play with the appliance. 

5. 

This appliance can be used by children aged from 8 years and above if they have been given 

supervision or instruction concerning use of the appliance in a safe way and if they understand the 
hazards involved. Cleaning and user maintenance shall not be made by children unless they are older 
than 8 and supervised. Keep the appliance and its power cord out of reach of children aged less than 
8 years. 

6. 

Appliances can be used by persons with reduced physical, sensory or mental capabilities or lack of 

experience and knowledge if they have been given supervision or instruction concerning use of the 
appliance in a safe way and understand the hazards involved.  

7. 

Children must not play with the appliance. 

8. 

If the supply cord or the detachable cord sets are damaged, it must be replaced by the manufacturer, 

its service agent or a similarly qualified person in order to avoid a hazard.

9. 

The detachable hose-sets and the connection kit used to connect the main water are supplied by 

the technician. Don’t reuse the old ones. 

10. 

The appliance is to be supplied through a residual current device (RCD) having a rated residual 

operating current not exceeding 30mA.

11. 

This appliance is intended to be used in household and similar applications such as 

 

- staff kitchen areas in shops, offices and other working environments; 

 

- farm houses and by clients in hotels, motels and other residential type environments; 

 

- bed and breakfast type environments; 

 

- catering and similar non-retail applications.

12. 

This appliance contains a UV-C emitter (UV lamp)

13. 

Unintended use of the appliance or damage to the housing may result in the escape of dangerous 

UV-C radiation. UV-C radiation may, even in little doses, cause harm to the eyes and skin. 

14. 

Appliances that are obviously damaged must not be used. 

15. 

The replacement of the UV lamp must be carried out by personnel trained by Waterlogic International 

or their approved distributors. 

16. 

Read the maintenance instructions before opening the appliance.

17. 

The appliance must be disconnected from the power supply before replacing the UV lamp.    

18. 

The UV lamp must be replaced at 6 month intervals or when necessary. If the unit is placed 

in a high use area, the UV lamp will need to be replaced more frequently. 
The quartz spiral can be cleaned by using an ultrasonic bath if needed.

19. WARNING:

 Do not operate the UV lamp when it is removed from the appliance enclosure.

Index

Technical Manual

Welcome to your new Waterlogic machine.  
This Technical Manual is to help you get great tasting water cup 
after cup by making the most of the product’s features.

Machine Overview 

 4

WL Cube Flow Diagram

 8

Pre Delivery Inspection Procedures (PDI) 

 9

Installation Procedures

 11

Operating Instructions

14

Maintenance and Servicing

16

Sanitizing

17

De-scaling

19

Advisory Icons

21

Fault Finding

22

Technical Specifications and Warranties 

24

End of Life

26

ROHS

26

BioCote®

26

Electrical Wiring Diagram 120V 

27

Electrical Wiring Diagram 230V

28

Dip Switch Setup

29

Wetted Parts List

32

Main Parts List

36

Summary of Contents for WL Cube Firewall

Page 1: ...WL Cube Firewall Technical Manual VERSION 1...

Page 2: ...10 The appliance is to be supplied through a residual current device RCD having a rated residual operating current not exceeding 30mA 11 This appliance is intended to be used in household and similar...

Page 3: ...any kinds of different filter combinations available from Waterlogic to suit local water conditions FIREWALL CHAMBER The Firewall chamber incorporates the in Faucet UV and is made of aluminium and is...

Page 4: ...the quartz spiral cleaned by using an ultrasonic bath if needed PCB The PCB Printed Circuit Board is the control unit for the Cube it is responsible for the functions of all the mechanical and electri...

Page 5: ...a trip hazard Keep them off the floor Take care not to allow the power lead to get wet If the lead gets wet it must not be used The Cube Technical Manual Version 1 May 2014 WL Cube Flow Diagram Cold...

Page 6: ...rocedures 1 Mount the Cube on a firm level surface so the machine cannot topple or fall over A 50mm air gap is required the whole way around the machine to allow for sufficient ventilation The Cube mu...

Page 7: ...The Cube should be sanitized at installation INSTALLATION KIT The Cube must be installed according to the local guidelines and it is advised that an installation kit be used A pressure reducing valve...

Page 8: ...Always place cup mug in the centre of the drip tray Always use a ceramic cup or a cup suitable for use with hot water Do not hold cup or place hands in dispensing area whilst dispensing water Do not...

Page 9: ...if there is any visible remove the loom and replace with a new one 9 Reconnect and replace the UV lamp assembly making sure not to touch the new UV lamp with bare hands as this will shorten the life...

Page 10: ...16 The machine will now begin to heat chill the water 17 Inspect the faucet nipple and clean or replace if it is damaged or if there any calcium built up around it 18 Using the antibacterial wipes su...

Page 11: ...panels of the machine including the drip tray and grill ADVISORY ICONS HOT WATER Press and hold the hot water icon for 3 seconds until the icon has illuminated orange select the dispense button and ho...

Page 12: ...rrectly and being turned on and off when you select the cold option 5 There is cold water flow but hot water is not flowing This may be due to calcium build up in the hot tank or the hot water outlet...

Page 13: ...t and continual improvement and therefore reserves the right to change specifications without prior notice other than in the case of significant changes Description Cube 120V HCA Cube 230V HCA Machine...

Page 14: ...into the surface of our products giving them built in sustainable antimicrobial protection BioCote s silver technology has been tested by an independent laboratory to show its ability to inhibit the g...

Page 15: ...rsion 1 May 2014 28 29 Electrical Wiring Diagram 230V Dip Switch Setup DANGER HIGH VOLTAGES PRESENT ON THIS PCB CARE MUST BE TAKEN WHEN LIVE TESTING THE CUBE MAIN PCB DIP SWITCHES 1 2 WITH INSTRUCTION...

Page 16: ...ERATURE SETTING Cold water temp range 5 c 10 c 15 c When reading this document please note the white coloring on the diagrams indicate the required position of the switch to determine the setting UV 1...

Page 17: ...Blue O D 1 4 13 JG Equal Tee Connector 1 4 14 JG Equal Elbow Connector 1 4 15 JG LLD PE Tube Blue O D 1 4 16 Solenoid Valve 24 DC Single Spring Load 17 JG Stem Elbow Connector 1 4 1 4 18 Drain valve...

Page 18: ...nector 1 4 36 JG LLD PE Tube Blue O D 1 4 37 JG LLD PE Tube Blue O D 1 4 38 Solenoid Valve 24 DC Single Spring Load 39 JG Equal Tee Connector 1 4 40 JG Stem Elbow Connector 1 4 1 4 41 JG Equal Tee Con...

Page 19: ...stem Elbow connector 15 Solenoid Valve 24 DC Single Spring Load 16 Cube cold tank 1 4 Litre 17 Compressor 18 Domestic Filter Dryer Chinese 19 WL Cube Side panel right Silver 20 BulkHead Fitting 1 4 x...

Page 20: ...use WL Label 37 Hot Cold Solenoid Valve 24V 300mm CUBE 38 1 4 Equal Tee Connector ST 39 UV 15 W Electronic Ballast Ver 3 40 Power Transformer 41 WL Cube Electronics cover Black 42 WL Cube UI Label WL...

Page 21: ...eacon Court Sandyford Dublin 18 Ireland www waterlogic com Waterlogic USA 11710 Stonegate Circle Omaha NE 68164 Speak to a Water Expert Rest of the world exportsales waterlogic com 353 1 293 1960 USA...