The Cube Technical Manual - Version 1, May 2014

10

11

1. 

Remove packing straps and unpack unit and visually inspect for any damage.

(Report any defects to Waterlogic as soon as possible).
2.

 Place the unit on a suitable work bench.

3.

 Open the top cover by removing the two screws that fix it in place.

4.

 Visually inspect all electrical connections and power lead.

5.

 Visually inspect all water connections.

6.

 Remove the three screws on top of the Firewall Chamber; you may need to 

remove some of the screws holding the top shelf in place to gain access to the 

Chamber. Inspect the quartz spiral for damage and re-assemble. 

7.

 Connect to a potable drinking water supply via a 1/4” John Guest tube, the supply 

must be limited to 3bar.

8.

 Connect the power cord to an appropriate power supply and the machine.

9.

 Replace the top cover and re-fit the screws.

10.

 Note that the hot tank must be filled before any other tank.

11.

 Select the hot button and then the dispense button until water flows clearly, you 

must dispense at least 200ml of water using the hot option for the tank to begin 

heating the water.

12.

 Select the cold button and then the dispense button until water flows clearly.

13.

 After cold/hot has filled, turn on heater/compressor switch allow up to an hour 

for the unit to heat and chill. Test water temperatures and ensure the water tastes 

acceptable.

14.

 Check all of the functions of the Cube.

15.

 Turn off the power and water.

16.

 Turn unit around and drain from rear drain valves if fitted.

17.

 Clean and repack ready for dispatch.

18.

 Waterlogic recommend that all units are fully electrically (PAT) tested on site by 

the commissioning engineer as damage may have occurred during transit to the 

unit’s final destination.

Installation Procedures

1.

 Mount the Cube on a firm, level surface so the machine cannot topple or fall 

over. A 50mm air gap is required the whole way around the machine to allow for 

sufficient ventilation. The Cube must not be installed in direct sunlight, adjacent to a 

heat source, or in an ambient room where the temperature is above 30°C or below 

5°C.

2.

 It is advisable that the power and water supply be within a 2 metre range of 

the machine, the isolation for the water and electricity should be easily accessible. 

The supply of water must be from a potable source and the machine should not be 

installed using an extension lead.

3

. Make the water connection to the Cube via a length of ¼” flexible pipe; with 

the pressure reducing valve that has been supplied installed 20cm away from the 

machine before the connection into the back of the machine is made. This will 

bring the pressure down to the ideal working pressure of 3bar. Minimum operating 

pressure for the machine to work suitably is 2.6bar. The minimum incoming flow rate 

is 1.2 litres per minute. At pressures higher than 3.2bar the machine will not function 

correctly and this can lead to leaks. The water should be from a potable source and 

should be allowed to run clear of any sediment before making the connection to the 

Cube.

4.

 Check the wall socket (polarity) and then make the electrical connection to the 

Cube by plugging the power lead in to the socket at the rear of the machine. Then 

connect it to the electrical feed or wall power outlet. Turn on the power supply to 

the Cube.

5.

  Turn on the red switch at the back of the Cube, the machine will now run through 

a self test cycle. Once the self test cycle has completed the filter(s) will need to be 

flushed.

6.

  Select the ambient water icon and then the central dispense button and dispense 

10 liters of water. This will remove excess carbon fines and sufficiently generate the 

filter.

Pre Delivery 

Inspection Procedures (PDI)

Summary of Contents for WL Cube Firewall

Page 1: ...WL Cube Firewall Technical Manual VERSION 1...

Page 2: ...10 The appliance is to be supplied through a residual current device RCD having a rated residual operating current not exceeding 30mA 11 This appliance is intended to be used in household and similar...

Page 3: ...any kinds of different filter combinations available from Waterlogic to suit local water conditions FIREWALL CHAMBER The Firewall chamber incorporates the in Faucet UV and is made of aluminium and is...

Page 4: ...the quartz spiral cleaned by using an ultrasonic bath if needed PCB The PCB Printed Circuit Board is the control unit for the Cube it is responsible for the functions of all the mechanical and electri...

Page 5: ...a trip hazard Keep them off the floor Take care not to allow the power lead to get wet If the lead gets wet it must not be used The Cube Technical Manual Version 1 May 2014 WL Cube Flow Diagram Cold...

Page 6: ...rocedures 1 Mount the Cube on a firm level surface so the machine cannot topple or fall over A 50mm air gap is required the whole way around the machine to allow for sufficient ventilation The Cube mu...

Page 7: ...The Cube should be sanitized at installation INSTALLATION KIT The Cube must be installed according to the local guidelines and it is advised that an installation kit be used A pressure reducing valve...

Page 8: ...Always place cup mug in the centre of the drip tray Always use a ceramic cup or a cup suitable for use with hot water Do not hold cup or place hands in dispensing area whilst dispensing water Do not...

Page 9: ...if there is any visible remove the loom and replace with a new one 9 Reconnect and replace the UV lamp assembly making sure not to touch the new UV lamp with bare hands as this will shorten the life...

Page 10: ...16 The machine will now begin to heat chill the water 17 Inspect the faucet nipple and clean or replace if it is damaged or if there any calcium built up around it 18 Using the antibacterial wipes su...

Page 11: ...panels of the machine including the drip tray and grill ADVISORY ICONS HOT WATER Press and hold the hot water icon for 3 seconds until the icon has illuminated orange select the dispense button and ho...

Page 12: ...rrectly and being turned on and off when you select the cold option 5 There is cold water flow but hot water is not flowing This may be due to calcium build up in the hot tank or the hot water outlet...

Page 13: ...t and continual improvement and therefore reserves the right to change specifications without prior notice other than in the case of significant changes Description Cube 120V HCA Cube 230V HCA Machine...

Page 14: ...into the surface of our products giving them built in sustainable antimicrobial protection BioCote s silver technology has been tested by an independent laboratory to show its ability to inhibit the g...

Page 15: ...rsion 1 May 2014 28 29 Electrical Wiring Diagram 230V Dip Switch Setup DANGER HIGH VOLTAGES PRESENT ON THIS PCB CARE MUST BE TAKEN WHEN LIVE TESTING THE CUBE MAIN PCB DIP SWITCHES 1 2 WITH INSTRUCTION...

Page 16: ...ERATURE SETTING Cold water temp range 5 c 10 c 15 c When reading this document please note the white coloring on the diagrams indicate the required position of the switch to determine the setting UV 1...

Page 17: ...Blue O D 1 4 13 JG Equal Tee Connector 1 4 14 JG Equal Elbow Connector 1 4 15 JG LLD PE Tube Blue O D 1 4 16 Solenoid Valve 24 DC Single Spring Load 17 JG Stem Elbow Connector 1 4 1 4 18 Drain valve...

Page 18: ...nector 1 4 36 JG LLD PE Tube Blue O D 1 4 37 JG LLD PE Tube Blue O D 1 4 38 Solenoid Valve 24 DC Single Spring Load 39 JG Equal Tee Connector 1 4 40 JG Stem Elbow Connector 1 4 1 4 41 JG Equal Tee Con...

Page 19: ...stem Elbow connector 15 Solenoid Valve 24 DC Single Spring Load 16 Cube cold tank 1 4 Litre 17 Compressor 18 Domestic Filter Dryer Chinese 19 WL Cube Side panel right Silver 20 BulkHead Fitting 1 4 x...

Page 20: ...use WL Label 37 Hot Cold Solenoid Valve 24V 300mm CUBE 38 1 4 Equal Tee Connector ST 39 UV 15 W Electronic Ballast Ver 3 40 Power Transformer 41 WL Cube Electronics cover Black 42 WL Cube UI Label WL...

Page 21: ...eacon Court Sandyford Dublin 18 Ireland www waterlogic com Waterlogic USA 11710 Stonegate Circle Omaha NE 68164 Speak to a Water Expert Rest of the world exportsales waterlogic com 353 1 293 1960 USA...

Reviews: