The Cube Technical Manual - Version 1, May 2014
12
13
7.
The hot water tank now needs to be filled, this is done by selecting the hot water
icon, then followed immediately by pressing and holding the main dispense button
until the tank has completely filled and water is being dispensed. Flush through 5
litres of water by continuing to select the hot option. Then repeat this process again
for the cold option.
8.
After making sure the hot tank is full of water then turn on the green heater and
compressor switch at the rear of the machine.
9.
Select the hot icon, then select and hold the main dispense button immediately
after selecting the hot icon.
10.
Dispense at least 200ml of hot water.
11.
The machine will now begin to heat / chill the water.
12.
The water temperatures are pre-set at the factory to 5°c for the cold water and
87°c for the hot water.
13.
The water should now be taste tested, any hint of taste in the water means
the machine needs to be flushed further with an additional 10 litres and then taste
tested again.
14.
The Cube should be sanitized at installation.
INSTALLATION KIT
The Cube must be installed according to the local guidelines and it is advised that
an installation kit be used. A pressure reducing valve is supplied with the Cube and
must be installed 20cm away from the back of the machine as part of the installation;
the pressure reducing valve is set to 2.8 bar.
• The Cube should not be connected to water supplies of unknown bacterial quality
or those not already fit for human consumption. The Cube should only be connected
to a Potable drinking water supply.
• The filter on the Cube must be changed every 12 months.
• The UV lamp on the Cube must be changed every 12 months.
• The cold tank should also be flushed and sanitised every 12 months.
• Waterlogic International strongly recommends the use of an anti-flood device.
• Figure 1 is the recommended installation kit.
Fig 1. Waterlogic
Installation Kit
1 - 15mm Compression Inlet
2 - Double Check Valve (great for carbonated water)
3 - Adjustable Pressure Reducing Valve
4 - Integral Isolator
5 - Pressure Gauge Port
6 - Waterblock
7 - 1/4” Pushfit Outlet
NOTE:
Should the incoming power to the Cube become interrupted users will
need to follow points 8-12 for water to be dispensed. (This is machine dependent).