CUBE DRAINING INSTRUCTIONS
WARNING!
CUBE IS A HEAVY OBJECT.
Use proper lifting aids and handling techniques to avoid injury. Use assistance as single person lift could
cause injury. Always drain before handling to reduce weight.
Draining Notes
There are 2 tanks and a booster pump circuit that must be drained in the
CUBE
. The booster pump will
have some water in the circuit that must be purged.
Prior to draining the hot tank, turn off both the
Green Heater/Compressor Switch and the Red
Power Switches located on back of the
Cube
and
dispense 2 liters of hot water from the machine.
I = ON, O= Off
As hot water is dispensed from the faucet of the unit, colder water will be introduced into the hot
tank. Since the Green Power Switch is turned off, the Heater will not energize and heat the incoming
tap water.
Following this precaution prevents exposing personnel and equipment (drains, catch basin, etc.) to
scalding hot water.
WARNING!
VERY HOT WATER CAN BURN OR SCALD.
Hot water should be dispensed carefully into insulated container to avoid injury.
Disable Cold and Hot Tanks
1.
Turn off the Green Power switch to disable the heater and compressor.
O=OFF
2.
Dispense 2 liters of water through the hot tank to cool the water
temperature in the hot tank and avoid burns.
WARNING!
VERY HOT WATER CAN BURN OR SCALD.
Hot water should be dispensed carefully into insulated container to avoid injury.
Turn off Water Supply and Bleed Water Pressure
3.
Isolate the unit from feed water by turning off the supply.
4.
Dispense cold still water to relieve any pressure built up in the system.
5.
Remove the water supply line from the unit.
6.
Install dust cap or plug into water supply line bulkhead fitting.
7.
Remove the Hot and Cold drain line cap and always allow tanks to drain.
8.
Reinstall all drain caps.
CUBE
Operating, Installation, and Service Manual
Page 24 - Revision: 6-23-2015