31.
Reconnect and replace the UV lamp assembly. Take care to not touch the new UV lamp with
bare hands, as this will shorten the life of the lamp. Replace the UV lamp protective cover.
CAUTION!
UV SYSTEM IS FRAGILE.
Never handle the UV lamp or Quartz Sleeve with
bare hands. UV Lamp and quartz sleeve must be free of oils and contaminants to ensure
proper operation. Use a soft non-abrasive cloth to clean.
32.
Inspect all of the electrical and water connections on the machine. Take any action necessary
to prevent a fault from occurring.
33.
Remove the new filter cartridge from the packaging and fit
it by firmly pushing it into the filter head, making sure it is
firmly and securely fitted.
34.
Screw the filter body to the filter head, making sure it’s
securely tightened.
35.
Fit the filter assembly into the machine as follows:
A.
Insert the filter assembly back into its cradle,
aligning the two male spigots with the female holes
in the cradle
B.
Push it firmly until the filter sits snugly and is flush
with the cradle top surface
C.
Lock the filter by closing the locking lever until it
‘clicks’ into place
CUBE
Operating, Installation, and Service Manual
Page 33 - Revision: 6-23-2015