TROUBLESHOOTING
Cold Water is not Cold (41
°
+/- 5
°
F)
Possible Reason
Solution
No power or refrigeration
elements
Check that the Green Heater and
Compressor switch is on.
Turn Green Heater and Compressor Switch
on.
I = ON
Tank has run out of cold water.
Cold tank capacity is 1.4liters.
Wait for cold tank to chill water to temperature prior to
dispensing more cold water.
A greater capacity of
Waterlogic
Water Systems is available.
Cold Water Thermostat
Check continuity of thermostat with multimeter. Replace
thermostat as required.
Refrigerant has run out
Run compressor for at least ten minutes. If condenser is not
warm then refill the refrigerant.
Compressor problem
If compressor is not running, repair or replacement is
needed.
Note: The Waterlogic Firewall reduces 7-log of waterborne bacteria, 5-log of viruses, and 4-log of
parasites potentially found in the drinking water. A small amount (about 2-ounces) of water remains in
the Firewall device after dispensing. This water does not remain permanently chilled, and will
eventually become room temperature after several hours. To ensure the next glass of water dispensed
is adequately chilled, Waterlogic recommends dispensing one 5-ounce or more cup of water after long
periods of inactivity. The first 2-ounces will be near room temperature, and the remaining 3+ ounces
will be very cold. The mixture of these two temperatures will provide for an adequately refreshing, cold
drink.
CUBE
Operating, Installation, and Service Manual
Page 71 - Revision: 6-23-2015