WL100
Manual Page 22 Revision: 1‐14‐2019
REPLACEMENT COMPONENTS
Component
WLCP Part No.
Frequency of Replacement
Hot Tank
Factory Setting ‐ 85°C (185°F)
12‐5615
Replace every 3 to 5 years
depending on usage.
Factory Part No HT‐3041
GAC Filter ‐ 10" Carbon
Activated Inline Filter ‐
Optional
FT‐0035‐IL‐WTL
Every 6‐months or as required.
Filter Element PN FT‐0038‐WLT
Carbon Filter 1‐micron 10"
Inline CBC Filter Assembly
Optional
FT‐0034‐IL‐WLT
Every 6‐months
or as required.
Filter Element PN FT‐0036‐WLT
Replacement parts can be obtained from
Waterlogic
or an
Authorized Waterlogic Dealer
.
See Parts Layouts, Drawings, and Lists for additional repair parts.
Hot Tank Service
Hot Tanks (with controls) must be replaced at least every 3‐5 years depending on usage. Descaling
Hot Tank may be required on a regular basis depending upon filtration and local water conditions.
See Hot Tank Descaling Instructions Section of this manual.
Surface Cleaning
Clean on a regular basis with damp lint free cloth. Never use harsh chemicals (alcohol or acid based)
or abrasive agents on any part of the product to avoid damage. A mild cleaner such as Simple green
or equivalent is recommended.
DISPOSAL
End of Life
At the
end of this product’s life
, ensure that it is disposed of in an environmentally friendly manner
which is fully compliant
with all Federal/State/Local Requirements and Guidelines.
Do not dispose
of this appliance with normal household or business waste.