background image

 

WL100

 Manual                                                                     Page 44                                                                      Revision: 1‐14‐2019 

6.

 

Remove the Hot and Cold water supply lines from the inlet line Solenoids. 

 
7.

 

Disconnect tank line outlet lines from Hot and Cold Solenoids to drain into basin or bucket. 

 
 
 
 
 
 
 
 
 
 
 
 

8.

 

Turn outlet fittings outward to avoid water spilling onto the Compressor. 

 
 
 

 
 
 
 
 
 
 
 
 
 
 

9.

 

Reconnect Tubing into Outlet Elbows once drained. 

 

10.

 

Dry inside of Bottom Tray as necessary. 

 

11.

 

Replace Lower Front Panel 
 

 
 
 
 
 
 
 

 

 

Summary of Contents for WL100

Page 1: ...0 Stonegate Circle Omaha NE 68164 800 288 1891 www waterlogicdealers com Tech Portal Website techportal waterlogic com Waterlogic International LTD Global Headquarters Grenfell Road Maidenhead Berkshi...

Page 2: ...o are experienced in the installation function and repair of Waterlogic equipment This publication is written for use by these qualified individuals Waterlogic encourages users to learn about products...

Page 3: ...Overload High Limit Safety 15 Hot Tank Descaling 17 Adjusting Cold Water Set Point 19 Programming Disabling Energy Saving Sleep Mode 20 Programming Changing Hot Water Mode to Ambient 21 Replacement C...

Page 4: ...tructions for future use DANGER This product can cause death or severe injury if incorrectly operated installed or maintained The installation maintenance sanitizing and any repair must be performed b...

Page 5: ...y potential microbiological contaminates CAUTION INDOOR USE ONLY Intended for Household Use Never expose to direct sunlight heat sources or ambient air temperature above 37 C 100 F or below 2 C 35 F I...

Page 6: ...tect from cross contamination Large Dispense Area 21 6 cm 8 5 inch dispense height to accommodate most cup and bottle sizes Child Safeguard The WL100 Water Treatment System requires user to select and...

Page 7: ...r Quality Association WQA to NSF ANSI 61 Section 9 Energy Star Certified The WL100 Water Treatment System has been tested and certified to the Energy Star a US Environmental Protection Agency EPA prog...

Page 8: ...old Tank Size 2 Liter 0 5 Gallons Hot Water Temperature 85 C 185 F Factory Set Point Hot Water Manual Reset Overload 105 C 221 F Hot Tank Size 1 6 Liter 0 4 Gallons Recommended Service Pressure 40 60...

Page 9: ...not fit between countertops and cabinets Check installation to ensure adequate clearance SHIPPING SPECIFICATIONS ITEM WL100 Counter Top WL100 Tower Width Depth Height 38 cm x 45 cm x 46 5 cm 15 x 17 7...

Page 10: ...trol Panel for the Waterlogic WL100 Water Treatment System For Cold Water Press the Blue Cold Water Select Button For Hot Water Press the two Red Hot Water Select Buttons at the same time This is a Sa...

Page 11: ...c for evaluation The form is available at www waterlogic us Supporting documentation must include but is not limited to proof of purchase installation date failure date and supporting installation and...

Page 12: ...NGER HIGH VOLTAGE ELECTRICAL HAZARD Unplug before inspection and service 2 Ensure there is adequate minimum of 5 cm 2 inches clearance around the unit and clean the Condenser Grill and Compressor fan...

Page 13: ...is a small hole in the side of the tank outlet tube that allows air and water to pass into the vent chamber as it is heated Water in the vent chamber is suctioned back through the outlet tube vent hol...

Page 14: ...WL100 Manual Page 14 Revision 1 14 2019 HEATER CIRCUIT...

Page 15: ...r coils on the rear of the unit you will see the Hot Tank located on the right hand side 5 From the Front of the Water Treatment System reach up behind the Hot Tank and take hold of the protective met...

Page 16: ...the Protective Metal Box so it snaps back into its original position on the Hot Tank 8 Replace the Lower Front Panel 9 Plug in the Power Cord 10 Turn on the Red Compressor Heater Switch I ON position...

Page 17: ...aterial Safety Data Sheet for specific requirements of each product CAUTION STAINLESS STEEL TANK DESCALING The Hot Tank is made from stainless steel Ensure descaling solution is compatible with stainl...

Page 18: ...Filters WARNING HOT WATER Unit produces Hot Water up to 87o C 189o F Water above 52o C 125o F can cause severe burns or scalding Hot water should be dispensed carefully into insulated container to avo...

Page 19: ...w under the decal at the rear of the unit Remove the red portion of the Cold Tank Temperature label to access the adjustment screw The factory set point is 41 F and is indicated by the dot on sheet me...

Page 20: ...pense has not been used for 3 hours Selecting any button wakes up the WL100 Water Treatment System and turns the Heater circuit back on The Hot Tank will typically take less than 10 minutes to heat th...

Page 21: ...d to Ambient Cold settings On the Energy Saver PCB move the Jumper on JP9 from Pins 1 and 2 to Pins 2 and 3 Unplug Power Cord and remove Top Cover to access Energy Saver PCB Hot and Cold Factory Setti...

Page 22: ...r additional repair parts Hot Tank Service Hot Tanks with controls must be replaced at least every 3 5 years depending on usage Descaling Hot Tank may be required on a regular basis depending upon fil...

Page 23: ...WL100 Manual Page 23 Revision 1 14 2019 WL100 COUNTER TOP DRAWINGS AND PARTS LIST Yellow Consumables Green Recommended spare parts Wetted Parts...

Page 24: ...2 each for every 10 units purchased EL 0159 L00 00 Yes 1 3 12 1303 Hot Tank Thermostat 85 C 185 F Recommend stocking 2 each for every 10 units purchased HT 3013A Yes 3 12 5665 Solenoid Valve with Ter...

Page 25: ...rcoal No Logo Recommend stocking 5 each for every 10 units purchased PL 1361 L00 CL Yes 20 0070 Drip Tray Body Blue No Logo Recommend stocking 5 each for every 10 units purchased PL 1361 Yes Remainder...

Page 26: ...ert Panel when purchasing also request Hot Water Caution Label LP 7169 12 0001 to adhere to front of this Panel PL 1365 Yes 18 1 12 0001 Hot Water Caution Label Adhere to Front Upper Drip Tray Insert...

Page 27: ...ter Bracket Counter Top Only ST 8152 B Yes 26 12 3150 Unit Rubber Feet Counter Top Only PL 1251 CN Yes 27 12 3170 Bottom Panel Counter Top Only ST 8151 A Yes 28 10 3067 Bulkhead Union x John Guest P N...

Page 28: ...8253 No 35 NA JG LLD PE Tube Blue O D 1 4 John Guest P N PE 08 BI 1000F B PU 4031 Purchase from John Guest 36 NA 5 16 X Reducing Elbow John Guest P N PI211008S PU 4007 Purchase from John Guest 37 10 3...

Page 29: ...WL100 Manual Page 29 Revision 1 14 2019 WL100 TOWER DRAWING AND PARTS LIST Yellow Consumables Green Recommended spare parts Wetted Parts...

Page 30: ...g 2 each for every 10 units purchased ST 8290 Yes 1 2 EL 0159 Overload with Manual Reset 97 C 207 F Recommend stocking 2 each for every 10 units purchased EL 0159 L00 00 Yes 1 3 12 1303 Hot Tank Therm...

Page 31: ...ommend stocking 5 each for every 10 units purchased PL 1361 L00 CL Yes 20 0070 Drip Tray Body Blue No Logo Recommend stocking 5 each for every 10 units purchased PL 1361 Yes Remainder of Parts 10 20 1...

Page 32: ...ST 8249 A Yes 18 12 8058 Side Panel Plastic Handle Tower Only PL 1123 Yes 19 20 0025 Front Lower Panel Tower Only PL 1364 Yes 20 20 1055 Front Lower Insert Panel Charcoal Tower Only PL 1363 L00 CL Ye...

Page 33: ...Only CO 9027 Special Order 28 19 1015 Gasket for Power Socket ST 8052 Yes 29 TBD Socket for Plug Connection EL 0061 L00 00 Yes 30 10 3014 Fuse Holder and Fuse 120V 15A with One Wire EL 5053 Yes 30 1 1...

Page 34: ...I 1000F B PU 4031 Purchase from John Guest 39 NA 1 4 Equal Elbow Connector John Guest P N P10308S PU 4008 Purchase from John Guest 40 Purchase from John Guest 5 16 X Reducing Elbow John Guest P N PI21...

Page 35: ...WL100 Manual Page 35 Revision 1 14 2019 WL100 WATER FLOW DIAGRAM Incoming Water...

Page 36: ...ual Page 36 Revision 1 14 2019 WL100 ELECTRICAL DIAGRAM DANGER HIGH VOLTAGE ELECTRICAL HAZARD PCB Printed Circuit Board contains High Voltage Only trained and qualified technicians should attempt live...

Page 37: ...rain with paper clips erasers napkins tea bags gum and various other intended items Waterlogic recommends you establish a minimum of weekly visits to the machine for cleaning of the drip tray drain Ma...

Page 38: ...ainer and drain basin will be required to catch the water from the faucet WARNING Use Personal Protective Equipment Gloves and Eye Protection Required The first 8 or 11 Liters 2 or 3 gallons of water...

Page 39: ...he cold circuit Chlorine test strips can be used to evaluate the water 12 Once the sanitizer odor taste has been flushed out of the cold side of the machine the sanitization process for the Cold Circu...

Page 40: ...e the Heater approximately 10 minutes to heat the water from ambient 24 C 75 F to the factory set point of 85 C 185 F Dispense a cup of hot water to ensure the temperature odor taste is acceptable WAR...

Page 41: ...ncoming tap water Following this precaution prevents exposing personnel and equipment drains catch basin etc from scalding hot water Disable Cold and Hot Tanks 1 Turn off the Red Heater and Compressor...

Page 42: ...ont Panel 8 Unclip the White Red and Black wire connectors from PCB to allow Front Cover to be removed 9 Remove Front Panel 10 Disconnect tubing to allow water to drain from the WL100 Water Treatment...

Page 43: ...ater will not energize and heat the incoming tap water Following this precaution prevents exposing personnel and equipment drains catch basin etc to scalding hot water Red Compressor Heater Switch mus...

Page 44: ...e Solenoids 7 Disconnect tank line outlet lines from Hot and Cold Solenoids to drain into basin or bucket 8 Turn outlet fittings outward to avoid water spilling onto the Compressor 9 Reconnect Tubing...

Page 45: ...on CAUTION USE A WATER PRESSURE REGULATOR Waterlogic will not be responsible for injury or damage caused by excessive water pressure Operating pressure must be 40 psi to 60 psi Be aware any of potenti...

Page 46: ...must be in the O OFF position while the Hot Tank is empty Damage could occur within one minute and the overload high limit will require manual reset if Heater is turned on with an empty Hot Tank 6 Mo...

Page 47: ...ing 1 Red Heater and Compressor Power Switch won t light and the Red LED on the Front won t light Possible Reason Solution Circuit Breaker Check the Circuit Breaker Fuse is Blown Replace Fuse Defectiv...

Page 48: ...CP PN 20 0040 Bad Energy Saver PCB Replace Energy Saver PCB Part Number EN 6131 WLCP PN 20 0075 Defective Red Heater Compressor Switch Replace Red Heater Compressor Switch 3 Compressor Runs But Does N...

Page 49: ...ater and Compressor Switch on I ON Compressor Starting Circuit Turn Red Heater and Compressor Switch off O OFF Remove the Compressor cap on side of the Compressor Disconnect the black and red terminal...

Page 50: ...of Faucet Vent Hole 6 Restricted Flow of Hot Water 7 Hot Water Drip out of Faucet 8 Dispenses Hot and Cold Water at the same time 9 No cold water available 10 Water does not dispense from unit 11 Col...

Page 51: ...button Does the Solenoid open without water pressure to the unit Listen for Solenoid to activate not to mistaken for the button click Adjust water pressure to 40 60 psi The correct input water pressu...

Page 52: ...ust water pressure to 40 60 psi The correct input water pressure is critical to the performance of the unit to allow Solenoids to open Stem of the switch is broken on the PCB Printed Circuit Board Rem...

Page 53: ...sure gauge Additional method of verification is to turn off water to unit and press the dispense button Does the Solenoid open without water pressure to the unit Listen for Solenoid to activate not to...

Page 54: ...it Inspect and replace tubing as necessary Faucet nipple screen mesh has obstruction s Unscrew faucet nipple from faucet and remove any obstruction s from screen mesh Exhausted Filter Replace the Filt...

Page 55: ...in its base This ensures the reservoir is always full by allowing more water in than out There is a small hole in the side of the tank outlet tube that allows air and water to pass into the vent chamb...

Page 56: ...without water pressure to the unit Listen for Solenoid to activate not to mistaken for the button click Adjust water pressure to 40 60 psi The correct input water pressure is critical to the performa...

Page 57: ...n click Adjust water pressure to 40 60 psi The correct input water pressure is critical to the performance of the unit to allow Solenoids to open Closed Water Supply Valve Open the Water Supply Valve...

Page 58: ...nput water pressure is critical to the performance of the unit to allow Solenoids to open Closed Water Supply Valve Open the Water Supply Valve The unit is not properly plugged into electrical outlet...

Page 59: ...ater pressure at the inlet bulkhead with a water pressure gauge Additional method of verification is to turn off water to unit and press the dispense button Does the Solenoid open without water pressu...

Page 60: ...has an outlet restrictor to ensure the tanks remain full of water and water is controlled as it is released to the faucet The inlet Solenoid controls flow into the tanks The tanks will depressurize on...

Page 61: ...ng solution is compatible with stainless and always flush the unit completely Dispose in an environmentally safe manner Materials Needed Personal Protective Equipment Rubber or Nitrile Safety Gloves a...

Page 62: ...Filters WARNING HOT WATER Unit produces Hot Water up to 87o C 189o F Water above 52o C 125o F can cause severe burns or scalding Hot water should be dispensed carefully into insulated container to avo...

Page 63: ...s run out of cold water Cold Tank capacity is 2 liters Gallon Wait for Cold Tank to chill water to temperature prior to dispensing more cold water A greater capacity of Waterlogic Water Systems is ava...

Page 64: ...able to make Cold Ambient water refer to Disabling Sleep Mode instructions included further below in this Troubleshooting Section The WL100 Water Treatment System does NOT have Extra Hot capability an...

Page 65: ...ro OHM s on the meter Replace components as necessary Loose or improperly connected wire s to the heating element Hot Tank Visually inspect wire leads gong to the Hot Tank confirm proper connections t...

Page 66: ...pense has not been used for 3 hours Selecting any button wakes up the WL100 Water Treatment System and turns the Heater circuit back on The Hot Tank will typically take less than 10 minutes to heat th...

Page 67: ...oils on the rear of the unit you will see the Hot Tank located on the right hand side 5 From the front of the WL100 Water Treatment System reach up behind the Hot Tank and take hold of the Protective...

Page 68: ...op flap of the Protective Metal Box so it snaps back into its original position on the Hot Tank 8 Replace the Lower Front Panel 9 Plug in the Power Cord 10 Turn on the Red Compressor Heater Switch I O...

Page 69: ...d to Ambient Cold settings On the Energy Saver PCB move the Jumper on JP9 from Pins 1 and 2 to Pins 2 and 3 Unplug Power Cord and remove Top Cover to access Energy Saver PCB Hot and Cold Factory Setti...

Reviews: