WL100
Manual Page 69 Revision: 1‐14‐2019
PROGRAMMING “CHANGING HOT WATER MODE TO AMBIENT WATER “
The
WL100 Water Treatment System
comes with set to Hot / Cold, which can be changed to
Ambient / Cold settings. On the Energy Saver PCB, move the Jumper on JP9 from Pins 1 and 2 to
Pins 2 and 3.
Unplug Power Cord and remove Top Cover to access Energy Saver PCB.
Hot and Cold (Factory Settings)
Ambient and Cold
PCB Jumper JP9 (Pin Numbers 1 and 2)
PCB Jumper JP9 (Pin Numbers 2 and 3)
Energy Saver PCB – PN 20‐0075 – Factory PN EN‐6131
JP9
1
2
2
3
JP9 PIN NUMBERS
1
2
3