6.
Fill the Hot Tank. Hold a container under the
dispensing faucet. Press and hold down the Red-Hot
Safety Button (LEFT hand side) dispensing button
followed by the Pressing and Holding down the Hot
Dispensing Button at the same time until a continuous
flow of water is obtained. Once a continuous flow is
obtained, release the hot water dispensing button.
Hot Tank is now full.
7.
Verify that the UV lamp operates as expected.
WARNING!
ULTRAVIOLET RADIATION.
Protect
your skin and eyes against ultraviolet rays. Never
look directly at an operating UV light. Always
disconnect before removal.
8.
Move the
Waterlogic WL1000GF MAX Water
Treatment System
into its final operating position. Be
sure that a minimum of 50mm clearance is maintained
around both the sides and the back of the unit. This is
important to allow proper airflow and heat exchange
of refrigeration system.
9.
Level unit using the adjustable feet to level if
necessary. Never install on incline.
10.
Turn the Red Heater and Compressor Power Switch to
I=ON
position.
11.
When the unit has reached its Hot Temp Set Point, the heater will cycle off. When the unit has
reached its Cold Temp Set Point Temperature, the compressor will cycle off.
12.
Once the unit is at the target temperature(s), sample the water to ensure water meets
expectations and additional rinsing or adjustment is not required.
13.
Check the unit for any leaks.