WL1000GF MAX
Manual
Page 47 Revision 10-7-2017
2.
Cold Water Flows, Hot Water does not flow.
Possible Reason
Solution
No Hot Water
Verify the pipes feeding the Hot Water Tank.
Check that the mechanical water outlet faucet valve is
operating and the water flows through it.
3.
Low Flow of Water – Rated Service Flow is 1.89 Litres (0.5 gallons) per Minute
Possible Reason
Solution
Determine Flow of Water
Rated Flow Rate is 1.89 Litres (0.5 gallons) per minute
.
Check flow rate by dispensing into a container to measure
for one minute and measure the amount of water that was
dispensed.
Water pressure
Verify that the water pressure is at the recommended 2.7 to
4 Bar for
WL1000GF MAX Water Treatment System
to
operate properly. Check with pressure regulator.
Filter or Membrane blockage
Verify that the Reverse Osmosis filters or membrane are not
blocked.
Solenoid
Verify the inlet function solenoid functions.
Mechanical float valve
Verify the mechanical float valve is functioning correctly.
Reservoir is blocked
Check that the spout of the Reservoir is not blocked.
Faucet blocked
Check that the faucet valves have no blockage or restriction.
Check that the feed pipe to the faucet valves is not kinked.
Tanks not full
Verify the reservoir is full and water flows into the Hot and
Cold tanks. During excessively high machine usage, the
Reservoir water level may be low and this can affect the
water flow.
The RO system will need more time to refill the Reservoir.