                                                                   Page 34 – Revision 6‐28‐2019 

Red Compressor/Heater Switch must be in the O=OFF position while the Hot 
Tank is empty.  Damage could occur within one minute and the overload 
(high limit) will require manual reset if heater is turned on with an empty Hot 
Tank.  

 

  

15.

 

Turn on the water and plug the 

WL270

 

Water Treatment System

 to a power source.  Verify the 

power LED is illuminated on the front of the unit.  The unit should start to fill. 
 

16.

 

Once the reservoir has filled halfway with water, drop two more tablespoons of Sanitizer ‐ 
Household Bleach (5.25% Sodium Hypochlorite) or Citric Acid Based Cleaner in the reservoir.   
 

17.

 

Once the reservoir has filled, depress and hold the cold dispense button.  This action fills the cold 
tank.  There will be a pause of up to one minute before the water starts to dispense from the 

WL270

 

Water Treatment System

 Faucet. 

 

WARNING!

  

Use Personal Protective Equipment.  Gloves and Eye Protection Required.  The first 

2 or 3 gallons of water will contain concentrated sanitizer. Use extreme care!  

 

18.

 

Once the cold tank is filled (when the water starts streaming into the glass under the faucet, 
release the cold dispense button.  Depress and verify chlorinated dispenses from the Ambient 
faucet. 

 

19.

 

Depress and verify chlorinated water flows from the hot faucet. 

 

20.

 

After water flows from all 3 faucets, turn on the Red Compressor / Heater Switch.  

Red Compressor/Heater Switch must be in the I=ON position.

 

 

The compressor and Hot Tank heater systems will begin to operate.  The heater LED (not the 
word heater, but the LESD above the word “heater”), and the blue chilling LED on the front 
indication panel of the machine will be illuminated. 

 
21.

 

Allow the sanitizing solution to remain in the machine until the red heater LED turns off – about 
10 minutes. 

 

22.

 

Place a pitcher under the Cold Faucet of the 

WL270 Water Treatment System 

and dispense 1 

gallon of water.  Do the same with the Ambient and Hot Faucets. 

 

23.

 

Turn off the Red Compressor / Heater Switch.  Unplug the unit.  Switch off the cold and hot drain 
caps on the back of the unit.  Drain the 

WL270 Water Treatment System

, replace drain caps. 

Red Compressor/Heater Switch must be in the O=OFF position. 

Summary of Contents for WL270

Page 1: ...items Waterlogic recommends you establish a minimum of weekly visits to the machine for cleaning of the drip tray drain Washing of the Internal Plastic Reservoir Lid and Float Materials Needed Persona...

Page 2: ...an unused sponge or paper towels 5 Rinse well with clean water 6 While avoiding touching the wetted surfaces of the reservoir with your hands reinstall the Reservoir into the WL270 Water Treatment Sy...

Page 3: ...sure to replace your filters whenever you notice a decline in the performance whether it is a drop in flow rate and or pressure or an unusual taste in the water 9 Flush thoroughly per filter manufact...

Page 4: ...concentrated sanitizer Use extreme care 18 Once the cold tank is filled when the water starts streaming into the glass under the faucet release the cold dispense button Depress and verify chlorinated...

Page 5: ...or 5 minutes and allow sensor to cool before resuming operation 27 Replace the top cover 28 Once the reservoir has re filled verify that all of the sanitizer has been rinsed from the hot cold and ambi...

Page 6: ...owing this precaution prevents exposing personnel and equipment drains catch basin etc to scalding hot water Disable Cold and Hot Tanks 1 Turn off the Red Heater and Compressor Power Switch to disable...

Page 7: ...F 37 C or below 35 F 2 C Install indoors and keep unit away from excessive humidity Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refrigeration syst...

Page 8: ...servoir to fill 5 Fill the Cold Tank Hold a container under the dispensing faucet press and hold the cold dispensing button until a continuous flow of water is obtained Once a continuous flow is obtai...

Page 9: ...is important to allow proper airflow and heat exchange of refrigeration system 9 Level unit using the adjustable feet to level if necessary Never install on incline 10 Turn the Red Heater and Compres...

Reviews: