WL270
Manual
Page 34 – Revision 6‐28‐2019
Red Compressor/Heater Switch must be in the O=OFF position while the Hot
Tank is empty. Damage could occur within one minute and the overload
(high limit) will require manual reset if heater is turned on with an empty Hot
Tank.
15.
Turn on the water and plug the
WL270
Water Treatment System
to a power source. Verify the
power LED is illuminated on the front of the unit. The unit should start to fill.
16.
Once the reservoir has filled halfway with water, drop two more tablespoons of Sanitizer ‐
Household Bleach (5.25% Sodium Hypochlorite) or Citric Acid Based Cleaner in the reservoir.
17.
Once the reservoir has filled, depress and hold the cold dispense button. This action fills the cold
tank. There will be a pause of up to one minute before the water starts to dispense from the
WL270
Water Treatment System
Faucet.
WARNING!
Use Personal Protective Equipment. Gloves and Eye Protection Required. The first
2 or 3 gallons of water will contain concentrated sanitizer. Use extreme care!
18.
Once the cold tank is filled (when the water starts streaming into the glass under the faucet,
release the cold dispense button. Depress and verify chlorinated dispenses from the Ambient
faucet.
19.
Depress and verify chlorinated water flows from the hot faucet.
20.
After water flows from all 3 faucets, turn on the Red Compressor / Heater Switch.
Red Compressor/Heater Switch must be in the I=ON position.
The compressor and Hot Tank heater systems will begin to operate. The heater LED (not the
word heater, but the LESD above the word “heater”), and the blue chilling LED on the front
indication panel of the machine will be illuminated.
21.
Allow the sanitizing solution to remain in the machine until the red heater LED turns off – about
10 minutes.
22.
Place a pitcher under the Cold Faucet of the
WL270 Water Treatment System
and dispense 1
gallon of water. Do the same with the Ambient and Hot Faucets.
23.
Turn off the Red Compressor / Heater Switch. Unplug the unit. Switch off the cold and hot drain
caps on the back of the unit. Drain the
WL270 Water Treatment System
, replace drain caps.
Red Compressor/Heater Switch must be in the O=OFF position.