CAUTION!
FILTER FLUSH REQUIRED.
WL270
’s
are not supplied with filters. Filters should be configured to optimize your system.
Filters need to be configured and specified to do the job given the local water conditions, usage,
maintenance schedule, and placement restrictions.
In order for our filters to perform as represented and to provide the best quality water possible, it
is essential that filters be replaced periodically. The frequency of filter changes depends upon your
water quality and your water usage. For example, if there is a lot of sediment and/or particles in
your water, then you will have to change your filters more frequently than a location with little to
no sediment. Be sure to replace your filters whenever you notice a decline in the performance,
whether it is a drop in flow rate and/or pressure or an unusual taste in the water.
3.
Flush thoroughly per filter manufacturers’ recommendation with fresh water to drain.
4.
Once flushed, install the filters. Following the flow direction on the filters.
NOTE:
Filters should not be flushed prior to 24 hours before installation to limit Microbial
Growth.
If you intend to use the Waterlogic RO System, you must remove the filter plate supplied behind
the lower front panel (four screws total). The RO System then mounts on the rails just above the
compressor. Route the RO drain line through the port that is protected by the rubber grommet on
the back of the machine.
5.
Remove the lid to the
internal reservoir of the
WL270
.
6.
Pour 2 tablespoons of
Sanitizer - Household
Bleach (5.25% Sodium
Hypochlorite) or Citric
Acid Based Cleaner in
the reservoir.
7.
Replace the reservoir lid.
8.
Unplug (disconnect) one
of the white plastic
electrical connectors
supplying power to the
UV lamp.
This step will
prevent interaction
between the sanitizer
and the UV.
WL270