SERVICE REQUIREMENTS
WARNING!
Read and understand the contents of this manual before attempting to service
WL270. Failure to follow the instructions in this manual could result in death, serious personal
injury, or severe property damage. Only trained and qualified technicians should attempt to
install, maintain, or service Waterlogic Equipment.
1.
Visually inspect all electrical and water connections for signs of wear or damage.
DANGER!
HIGH VOLTAGE ELECTRICAL HAZARD.
Unplug before inspection and service.
2.
Waterlogic
recommends changing the UV Lamp every 12 months.
NOTE:
When replacing the UV lamp the wiring harness must also be
replaced.
NOTE:
The Glow Starter shown to the right, may appear blackened
which is normal.
WARNING!
ULTRAVIOLET RADIATION.
Protect your skin and eyes against ultraviolet rays.
Never look directly at an operating UV light. Disconnect before removing UV Lamp.
CAUTION!
UV LAMPS ARE HAZARDOUS.
Lamps are considered Hazardous Waste and must
be disposed of accordingly. Refer to Product MSDS sheet for details.
3.
Clean the quartz sleeve that surrounds the UV lamp with a non-abrasive cloth, descaling solution,
or ultrasonic bath if needed when changing UV lamps.
CAUTION!
UV SYSTEM IS FRAGILE.
Never handle the UV lamp or Quartz Sleeve with bare
hands. UV Lamp and quartz sleeve must be free of oils and contaminants to ensure proper
operation. Use a soft non-abrasive cloth to clean.
4.
Inspect the Quartz Sleeve O-ring for wear or damage and replace as necessary.
5.
Ensure there is adequate (minimum of 2”) clearance around the unit and clean the condenser grill
and compressor fan to provide efficient cooling system operation.
6.
Sanitize the cold tank per instructions in the pre-installation procedures.
7.
Clean and sanitize external surfaces of the unit. Use soap and water or chemicals that are
compatible with ABS plastic and will not damage or degrade the product surfaces.
8.
Remove and clean the Faucet. Replace as needed.
WARNING!
SANITIZER MAY CONTAIN HAZARDOUS CHEMICALS.
Use of proper personal
protective equipment such as rubber gloves and eye protection is required.
WL270
Operating, Installation, and Service Manual Page 20 - Revision: 4-7-2015