REPLACEMENT COMPONENTS
Component
Part No.
Frequency of Replacement
Quartz Sleeve for 8 Watt Lamp CT-2002
Clean 12 months, or as required
WLUSA Part No 10-1400
UV Lamp Assembly, 8 Watt
CT-2083
Every 12 months
WLUSA Part No 10-2350
Replacement parts can be obtained from
Waterlogic
or an
Authorized Waterlogic Dealer
.
See Parts Layouts, Drawings, and Lists for additional repair parts.
Hot Tank Service
Hot Tanks (with controls) must be replaced at least every 5 years. Descaling hot tank may be
required on a regular basis depending upon filtration and local water conditions. See Service Section.
NOTE
:
At the
end of this product’s life
, ensure that it is disposed of in an environmentally friendly manner
which is fully compliant
with all Federal/State/Local Requirements and Guidelines.
WL270
Operating, Installation, and Service Manual Page 21 - Revision: 4-7-2015