RESETTING THE OVERLOAD OR HIGH LIMIT SAFETY
1.
Turn off Red Heater and Compressor Power Switch on rear of unit.
2.
Unplug the Power Cord from rear of unit.
3.
Remove the Lower Front Panel of unit by removing the Phillips head screws underneath
the lower front panel.
4.
Locate the protective metal box on the rear of the hot
tank. As you look through the condenser coils on the
rear of the unit, you will see the hot tank located on the
right hand side.
5.
From the front of the Water Treatment System, reach
up behind the hot tank and take hold of the protective
metal box covering the thermostat and overload on the
hot tank.
There are nuts that secure the metal box to the hot
tank. However the nuts are loose enough to allow you
to remove the metal box.
If the nuts on the metal box are too tight, loosen the
nuts securing the hot tank to the upper base of the unit
and lower the hot tank so you can remove the metal
box.
For demonstrative purposes, photos below have
lowered the hot tank from the unit
.
WL270
Operating, Installation, and Service Manual Page 24 - Revision: 4-7-2015