WL2FLT
Manual Page 46
–
Revision 10-26-2021
3.
Dispensing Won’t Stop When Not Holding the Dispensing Button
Possible Reason
Solution
Too much water pressure.
Recommend 40 to 60 psi for
the
WL2FLT
Water Treatment
System
to operate properly.
The correct input water pressure is critical to the performance of
the unit to allow solenoids to open.
Check water pressure at the inlet bulkhead with a water pressure
gauge.
Additional method of verification is to turn off water to unit and
press the dispense button. Does the solenoid open without
water pressure to the unit? Listen for solenoid to activate, not
button “click”.
Adjust water pressure to 40-60 psi.
Bad Display PCB
Replace Main PCB
Debris in the Solenoid
Inspect Solenoid for debris and clean out as needed.
Dispensing Button Stuck
Dirt or Foreign material is filling the gap around the push-buttons.
Inspect the push buttons and clean surrounding area. Inspect
faucet assembly inside the unit and clean as necessary.
4.
Steady Drip Out of Faucet
Possible Reason
Solution
Debris in Solenoid
Inspect Solenoid for debris and clean out as needed.
5.
Hot Water or Steam Coming out of both the Faucet and Vent Hole
Possible Reason
Solution
Improper tubing attachment
from the Hot Tank to Faucet or
vice versa.
Check that the tubing is connected from Hot Tank Outlets to
correct Faucet attachments. Connect tubing to outlets as
needed.