4.
Turn off water supply and remove sanitizing cartridge from inlet water supply. Reconnect
water supply to inlet fitting.
5.
Allow descaling solution to remain in the Hot Tank for 15 minutes (length of time may vary
depending on water conditions).
6.
Place a pitcher, catch basin or other container under the faucet of the
WL3 FX Water
Treatment System
.
7.
Flush the Hot Tank until water runs clear.
8.
Once clear Water dispenses from the faucet the Hot Tank has been descaled. Always
ensure the
WL3 FX
Water Treatment System
is performing to the customer’s satisfaction.
WARNING!
HOT WATER HAZARD.
The
WL3 FX
Water Treatment System
Produces Hot
Water and Steam. Always use insulated and chemically compatible containers and let
WL3 FX
Water Treatment System
cool down before draining the hot tank to avoid
injury.
CAUTION
!
MUST
REPLACE HOT TANK
EVERY 3-5 YEARS DEPENDING ON USAGE
The Hot Tank and its controls must be replaced a minimum of every three to five years
depending on usage to ensure efficient and dependable operation.
WARNING!
REINSTALL ALL PANELS AND COVERS.
Always reinstall all Panels, protective
covers, and fasteners after servicing equipment. Failure to do so could result in severe