WL3 FX
Manual
Page 52 - Revision: 7-27-2022
you notice a decline in the performance, whether it is a drop in flow rate and/or pressure or
an unusual taste in the water.
2.
Flush thoroughly
per filter manufacturers’ recommendation
with fresh water to drain.
3.
Once flushed, install the filters. Following the flow direction on the filter.
NOTE:
Filters should not be flushed prior to 24 hours before installation to limit Microbial
Growth.
Sanitizing
Sanitize using a Household Bleach (5.25% Sodium Hypochlorite solution) or other approved
cleaner throughout the cold and sparkling water circuits. Follow all instructions on the
sanitizer and flush with fresh water through the faucet until odor and taste is acceptable.
WARNING!
USE PROPER PERSONAL PROTECTIVE EQUIPMENT
Always ensure proper ventilation and use proper personal protective equipment such as
gloves and eye protection when using chemicals. Refer to Material Safety Data Sheet for
specific requirements of each chemical product. Take all necessary precautions to
prevent sanitizer from contacting eyes, clothing, and any other surfaces in could damage
(carpets).
4.
Mix ½ gallon of sanitizer per directions or use Bleach Solution (1 teaspoon = 1/6 oz. = 5 ml =
½ cap full) of household bleach (Sodium Hypochlorite 5 - 10% Concentration) with 1/2
gallon of water inside Sanitizing Cartridge. Always ensure sanitizer is compatible with
stainless steel and acetyl plastic.
5.
Connect sanitizing cartridge to inlet water supply and connect to inlet bulkhead fitting on
back of unit. Turn on water supply.
6.
Connect power to WL350 Water Treatment System and turn on Red Power Switch. DO NOT
TURN ON GREEN COMPRESSOR & HEATER SWITCH AT THIS TIME. O=OFF
7.
Turn on water supply and check for leaks.
DANGER!
ELECTRICAL SHOCK HAZARD.
Do not plug in unit unless qualified. Only qualified personnel who have read and
understand this entire manual should attempt to install or service this unit.
CAUTION!
NEVER TURN ON HEATER BEFORE FILLING HOT TANK.