WL3 FX
Manual
Page 53 - Revision: 7-27-2022
Fill the Cold Circuit with Sanitizer
8.
Touch and hold the cold dispensing icon on the front control panel until cold
water/sanitizing solution comes out the faucet. Stop dispensing and allow sanitizer to sit in
cold tank for 10-15 minutes.
NOTE:
Container and drain basin will be required to catch the water from the faucet.
WARNING!
Use Personal Protective Equipment. Gloves and Eye Protection Required.
The first 2 or 3 gallons of water will contain concentrated sanitizer. Use extreme care!
Flushing the Sanitizer from the Machine
9.
Place a pitcher, catch basin, or other container under the faucet of the
WL3 FX Water
Treatment System.
10.
Flush the Cold Tank. Run several gallons of water through the faucet by dispensing cold
water to dilute and remove the sanitizer from the cold circuit. You can use chlorine test
strips to evaluate the water.
11.
Once the sanitizer odor/taste has been flushed out of the cold side of the machine the
sanitization process for the Cold Circuit is complete.
Fill the Hot Tank
12.
Tap, then press and hold the Hot Water icon, to fill the hot tank. Water will dispense from
the faucet once the hot tank is full. Flush until water is clear.
WARNING!
HOT CIRCUIT IS NOT SANITIZED.
Water in the hot circuit is not sanitary until the temperature exceeds 77
o
C (171
o
F) for at
least 5 minutes.
UV System Functional Test
WARNING!
ULTRAVIOLET RADIATION.
Protect your skin and eyes against ultraviolet
rays. Never look directly at an operating UV light. Disconnect wiring before removing.
13.
Reinstall the UV Lamp and connect the wiring.
14.
Dim or shield the overhead lights and peer into the machine, on top of the Cold Tank, at the
UV connector and retaining cap. The blue glow indicates that the lamp is lit.