WL3 FX
Manual
Page 54 - Revision: 7-27-2022
Compressor Test
15.
Switch Green Compressor / Heater to
I=ON position
.
Always ensure tanks
are full of water before turning on the heater
or the overload (high limit)
will open and require manual reset. If the wire condenser at back of the
WL3 FX
Water Treatment System
is warm, the refrigeration system is
working.
16.
Once the machine reaches its target temperature, the compressor will shut off. Draw a
glass of cold water and verify it has been chilled to proper temperature.
Heater Test
17.
Always ensure tanks are full of water before turning on the heater
or the overload (high
limit) will open and require manual reset. It will take the heater approximately 10 minutes
to heat the water from ambient 24°C (75°F) to the factory set point of 85°C (185°F).
Dispense a cup of hot water to ensure the temperature/odor/taste is acceptable.
WARNING!
HOT WATER. Unit produces Hot Water up to 87
°
C (188
°
F).
Water above
52
°
C (125
°
F) can cause severe burns or scalding. Hot water should be dispensed
carefully into insulated container to avoid injury.