WL3 FX TOWER DRAINING INSTRUCTIONS
Draining Notes
Drain the
WL3 FX
Water Treatment System
for transportation.
WARNING!
STORE UNIT EMPTY. ALWAYS SANITIZE BEFORE REUSE.
The unit must be completely drained and sealed before storing to avoid stagnation and
reduce microbial growth).
Prior to draining the Hot Tank, turn off the Green Heater and Compressor Power
Switch (
O=OFF)
, and dispense 2 liters of hot water from the machine. As hot water
is dispensed from the faucet of the
WL3 FX
Water Treatment System
, colder water
will be introduced into the hot tank. Since the Red Heater and Compressor Power
Switch is turned off, the heater will not energize and heat the incoming tap water.
Following this precaution prevents exposing personnel and equipment (drains,
catch basin, etc.) to scalding hot water.
Disable Cold and Hot Tanks
1.
Turn off the Green Heater and Compressor Power Switch (
O-OFF
) to disable the
heater and compressor.
2.
Dispense 2 liters of water through the Hot Tank to cool the water temperature in
the hot tank and avoid burns.
WARNING!
HOT WATER.
The
WL3 FX
Water Treatment System
produces Hot Water
up to 8
7°
C (188
°
F).
Water above 52
°
C (125
°
F) can cause severe burns or scalding. Hot
water should be dispensed carefully into insulated container to avoid injury.
Turn off Water Supply and Bleed Water Pressure
3.
Disconnect the
WL3 FX
Water Treatment System
from feed water.
4.
Dispense cold still water to relieve any pressure built up in the system.
5.
Insert approx. 3 inches of blue tubing into the Line Bulkhead fitting at back of the
WL3 FX
Water Treatment System
to allow water to drain out the inlet port.
6.
Press and hold the Cold Water Dispense Button until all Cold
Water has drained from the
WL3 FX
Water Treatment System
through the inlet port.
7.
Double press and hold the Hot Water Dispense Button until all Hot Water has
drained from the
WL3 FX
Water Treatment System
out of the inlet port. The
machine is now drained.
Bulkhead Fitting