Pre-installation and sanitization procedures as prescribed in this manual must be performed
before installing the
WL3 FX Water Treatment System
.
Always install indoors and place the
Waterlogic WL3 FX
Water Treatment System
on a firm, flat
and stable surface.
1.
Attach the water supply line
to the 1/4” feed water inlet
bulkhead fitting on the back of
the
WL3 FX
Water Treatment System.
Waterlogic
requires the use of a water pressure
regulator. Water feed pressure must be between 40-60 psi. Turn on the water supply
and check for leaks.
2.
Check to ensure that the Green Heater and Compressor Switch is the
O=OFF
position, and that the Red Power Switch is in the
I=ON
position
NOTE:
Switches have internal LED that illuminates when placed in
I=ON
position.
3.
Connect the power cord to the back of the
Waterlogic WL3 FX
Water Treatment System
and to a 120 Volt supply.
4.
Fill the Cold Tank. Hold a container under the dispensing faucet, press and hold the cold
dispensing button until a continuous flow of water is obtained. Once a continuous flow is
obtained, release the dispensing button. Cold tank is now full.
5.
Fill the Hot Tank. Hold a container under the dispensing faucet. Double press and hold
the Hot Dispense Button until a continuous flow of water is obtained. Once a continuous
flow is obtained, release the Hot Dispense Button. Hot tank is now full.
CAUTION!
NEVER TURN ON HEATER BEFORE FILLING HOT TANK.
Green Heater and Compressor Switch
must be in the O=OFF position while the
Hot Tank is empty. Damage could occur within one minute and the overload
(high limit) will require manual reset if heater is turned on with an empty Hot
Tank.
6.
Verify that the UV Lamp operates as expected.
WARNING!
ULTRAVIOLET RADIATION.
Protect your skin and eyes against ultraviolet
rays. Never look directly at an operating UV light. Always disconnect before removal.
7.
Move the
Waterlogic WL3 FX
Water Treatment System
into its final operating position.
Be sure that a minimum of 2” clearance is maintained
around both sides and the back of
the
WL3 FX
Water Treatment System
.
8.
This is important to allow proper airflow and heat exchange of refrigeration system.
9.
Level the
WL3 FX
Water Treatment System
using the adjustable feet to level if necessary.
Never install on incline.
10.
Turn the Green Heater and Compressor Switch to
I=ON
position.