WL3 FX
Manual
Page 61 - Revision: 7-27-2022
DISABLING ENERGY SAVING MODE
NOTE: THIS CHANGE MUST BE MADE WITH THE MACHINE OFF AND
UNPLUGGED. IF NOT DONE, THE CHANGE WILL NOT BE RECOGNIZED.
Note the DIP switches on the main PCB (the one mounted to the back
side of the front upper panel):
To DISABLE the energy saver, DIP #2 must be switched from ON to
OFF (Down position), as per the legend printed on the board. This will
enable the hot tank to cycle continuously. All units come with Sleep
Mode enabled.