HOT TANK OVERHEAT (ROR PROTOCOL TRIGGERED)
The
WL3 FX Water Treatment System
has an ROR (Rate of Rise) protocol in the
programming that will disable the hot tank and give audible and visual alarms if
the temperature in the Hot Tank rises too rapidly, which usually indicates dry
heating. The Hot Tank
MUST HAVE WATER IN IT
before the Green
heater/compressor switch is turned on. Heating without water can damage the
tank and the machine.
If this occurs, disconnect the machine from power for 10 seconds to allow the
alarm to reset. Turn OFF the Green switch. Reconnect to power, with the Red
Power switch ON and the Green switch OFF. Dispense water from the hot tank as
normal. Once water flows, turn the Green switch back ON. If there is no water
flowing from the hot tank, investigate further for other potential failures.
THIS ICON WILL
BLINK AND ALARM
WILL SOUND