WL3 FX
Manual
Page 64 - Revision: 7-27-2022
RESETTING THE HOT TANK OVERLOAD
The
WL3 FX Water Treatment System
has a Hot Tank equipped with a High Limit
or Overload Thermostat. This is to prevent damage to the unit if the temperature
in the Hot Tank gets too high. If the temp does get out of control, this Overload
Thermostat will break the electric connection, cutting power from the heating
element. The Overload Thermostat will have to be manually reset to continue
normal operation of the Hot Tank. The photos below outline how to access and
reset the mechanism.
Unplug the machine from power
. Remove the two screws at the back of the
top lid and remove.
With cover removed, locate and remove the two screws on the backside of the
front panel. Then locate and remove the three screws holding the Firewall in
place.
Tower models will require the lower front panel be removed as well
before continuing.