Page 67 - Revision: 7-27-2022
3.
Compressor Runs but Does Not Chill
Possible Reason
Solution
Condenser is dirty
Clean the condensing coil of any obstructions or dust.
Reduction of airflow into unit.
Make sure unit is not under minimum ventilation requirements (2
to 4 inches).
Compressor is running very
hot.
Low or lost refrigerant. Refrigerant recharge required.
4.
Compressor is Not Running
Possible Reason
Solution
Green Heater and Compressor
Switch button on unit is in the
off position
Turn Green Heater and Compressor Switch on.
I = ON
Compressor Starting Circuit
Turn Green Heater and Compressor Switch off.
O = OFF.
Remove the compressor cap on side of the compressor;
Disconnect the black and red terminal connectors;
Inspect the starter and overload relay for any defects.
Replace components(s) as needed.
Turn Red Heater and Compressor Switch on
I = ON
and retest
compressor operation.
5.
Red Power Switch is lit, but Green Power LED is not lit
Possible Reason
Solution
Machine is in Sleep Mode
Press any Dispense Button to wake the machine. Power LED should
become lit and Hot Tank will begin heating again.