WL3 FX
Manual
Page 69 - Revision: 7-27-2022
1.
Dispensing Won’t Stop
when Not Holding the Dispensing Button
Possible Reason
Solution
Too much water pressure.
Recommend 40-60 psi for the
WL3 FX Water Treatment
System
to operate properly.
The correct input water pressure is critical to the performance of
the unit to allow solenoids to open.
Check water pressure at the inlet bulkhead with a water pressure
gauge. Additional method of verification is to turn off water to unit
and press the dispense button. Does the solenoid open without
water pressure to the unit? Listen for solenoid to activate, not
button “click”.
Adjust water pressure to 40-60 psi.
Bad Display PCB
Replace Front PCB
Hot and Cold
–
P/N EN-6085 WLCP PN 12-8103
Cold Only
–
P/N EN-6086 WLCP PN 12-8615
Debris in the Solenoid
Inspect Solenoid for debris and clean out as needed.
Dispensing Button Stuck
Dirt or Foreign material is filling the gap around the push-buttons.
Inspect the push buttons and clean surrounding area. Inspect
faucet assembly inside the unit and clean as necessary.
2.
Water does not dispense from Unit
Possible Reason
Solution
Too much water pressure.
Recommend 40-60 psi for the
WL3 FX Water Treatment
System
to operate properly.
The correct input water pressure is critical to the
performance of the unit to allow solenoids to open.
Check water pressure at the inlet bulkhead with a water
pressure gauge. Additional method of verification is to turn
off water to unit and press the dispense button. Does the
solenoid open without water pressure to the unit? Listen for
solenoid to activate, not button “click”.
Adjust water pressure to 40-60 psi.
Closed water supply valve
Open the water supply valve.
The unit is not properly
plugged into electrical outlet
Check electrical outlet connection, or for blown circuit
breaker.
Green Heater and Compressor
Switch on unit is in the off
position
Turn Green Heater and Compressor switch on.
I = ON
15 Amp Fuse Blown
Replace the 15 Amp Fuse as needed.