WL3 FX
Manual
Page 76 - Revision: 7-27-2022
15. Run On
–
Water continues to dispense out of faucet after releasing the
dispense button
Reason
“Run On” or “Carry On” is present in all Waterlogic pressure fed units without outlet
solenoids.
“Run On” is defined is the amount of water that continues to dispense out
of the faucet after
releasing the dispense button.
Run On exists because the tanks pressurize as water is being dispensed. Every Waterlogic tank
has an outlet restrictor to ensure the tanks remain full of water and water is controlled as it is
released to the faucet. The inlet solenoid controls flow into the tanks. The tanks will
“depressurize” once the dispense button is released the inlet solenoid closes. A small amount
of water will “Run On” through the faucet as the tank depressurizes to atmospheri
c
conditions.
Typical “Run On” is 2
-3 seconds.
“Run On” can be reduced by installing a pressure limiting device.
The amount of inlet or supply pressure directly impacts the amount of “Run On” as quantified
below.
WLCP Lab Testing of Rn On 7-31-2013
Pressure
Pressure
Time
Flow Rate
Run On
Static PSI
Dynamic PSI
4 Liters
I/min
Seconds
68
40
61
2.9508197
3
50
30
72
2.5
2.5
32
20
92
1.956217
2
Pressure measured at inlet line to unit. Static with unit closed. Dynamic with unit
dispensing cold water.
No filters were installed in unit.