REPLACEMENT COMPONENTS
Component
Part No.
Frequency of Replacement
UV Light, 15 Watts
CT-2085-A
Every 6 months, or as required
WLCP Part No 12-8310
UV Spiral Quartz Sleeve
FU-0007
Clean every 12 months, replace as needed
WLCP Part No 12-8305
Hot Tank 85°C (185°F)
HT-3041
Replace every 3 to 5 years depending on usage.
WLCP Part No 12-5615
1-Micron CBC Cyst / Lead
Reduction Filter Assembly NSF
53 *
FT-0063
Every 6-months, or as required. Local water
conditions will determine proper filter type and
maintenance schedule. WLCP Part No FT-0063
* One pre-installed. One required for NSF-53 and NSF P231 Certification.
Replacement parts can be obtained from Waterlogic or an Authorized Waterlogic Dealer.
See Parts Layouts, Drawings, and Parts Lists for additional repair parts.
Hot Tank Service
Hot Tanks (with controls) must be replaced at least every 3 to 5 years depending on usage.
Descaling Hot Tank may be required on a regular basis depending upon filtration and local water
conditions. See Service Section.
NOTE:
At the end of this product’s life, ensure that it is disposed of in an environmentally friendly manner