WL350 Operating, Installation, and Service Manual Page 58 – Revision 8-30-2016
Dispensing Won’t Stop When Not Holding the Dispensing Button
Possible Reason
Solution
Bad Display PCB
Replace Main PCB
Part Number: EN-6126-L00-00 - WLCP PN 12-8355
Debris in the Solenoid
Inspect Solenoid for debris and clean out as needed.
Dispensing Button Stuck
Dirt or Foreign material is filling the gap around the push-buttons.
Inspect the push buttons and clean surrounding area. Inspect
faucet assembly inside the unit and clean as necessary.
Steady Drip Out of Faucet
Possible Reason
Solution
Debris in Solenoid
Inspect Solenoid for debris and clean out as needed.
Hot Water or Steam Coming out of both the Faucet and Vent Hole
Possible Reason
Solution
Improper tubing attachment
from the Hot Tank to Faucet or
vice versa.
Check that the tubing is connected from Hot Tank Outlets to
correct Faucet attachments. Connect tubing to outlets as
needed.