WL350 Operating, Installation, and Service Manual                                                                       Page 63 – Revision 8-30-2016 

No Water is Dispensing from One Side – Cold or Hot 

 
 

Possible Reason 

Solution 

Too much water pressure.   
 
Recommend 40 to 60 psi for 
the WL350 Water Treatment 
System
 to operate properly. 

Verify water pressure at the Inlet Bulkhead with a Pressure 
Regulator.   
 
Additional method of verification is to turn off water to unit and 
press the Dispense Button.  Does the Solenoid open without water 
pressure to the unit?  Listen for solenoid to activate, not the 
Dispense Button “click”. 
 
Adjust water pressure to 40-60 psi.  The correct input water pressure 
is critical to the performance of the unit to allow solenoids to open. 
 

PCB  

Switch the hot and cold wires on PCB (red and blue connections). 
 
If water now dispenses from the opposite side, this is an indication 
that there is a PCB problem. 
 
Replace PCB 

Solenoid  

If both the Water Pressure and PCB have been ruled out, then it is 
the Solenoid. 
 
Replace Solenoid. 

See “Green Flashing Light” 
Fault Code Section of this 
Manual
 

Indicates the Firewall UV system is not detecting adequate dose of 
UV to ensure safe water. 

 

 
Cold Water Dispenses from Faucet and Vent Outlet Simultaneously 

 
 

Possible Reason 

Solution 

Improper tubing attachment 
from the Cold Tank to Faucet 
or vice versa 

Verify tubing is connected properly from Cold Tank Outlets to 
correct Faucet attachments. 

Scale has formed inside Cold 
Tank outlet tube. 

Remove Cold Water Outlet Tube from Cold Tank to Faucet.  Pour 
some scale remover into Cold Tank. 

Expansion chamber in Cold 
Tank is not sealed properly. 

Replace Cold Tank. 

 
 

Summary of Contents for WL350

Page 1: ...aterlogic Commercial Products LLC 11710 Stonegate Circle Omaha NE 68164 800 288 1891 www waterlogic us Tech Portal Website www techportal waterlogic com WL350 OPERATING INSTALLATION AND SERVICE MANUAL...

Page 2: ...Dealers employ trained service personnel who are experienced in the installation function and repair of Waterlogic equipment This publication is written for use by these qualified individuals Waterlo...

Page 3: ...t Tank Descaling 18 Firewall Outlet Solenoid Reverse Flow Orientation 20 Adjusting Cold Water Set Point 21 Programming Disabling Energy Saving Sleep Mode 22 Programming Changing Hot Water Mode to Ambi...

Page 4: ...perly grounded outlet Unit should be protected by ground fault circuit interrupter GFCI or residual current device RCD having a rated residual operating current not exceeding 30mA Use only Waterlogic...

Page 5: ...ation and reduce microbiological contamination potential bacterial growth Sanitize before use to eliminate any potential microbiological contaminates CAUTION INDOOR USE ONLY Intended for household use...

Page 6: ...ation and reduce microbiological contamination potential bacterial growth Sanitize before use to eliminate any potential microbiological contaminates CAUTION INDOOR USE ONLY Intended for household use...

Page 7: ...essed Faucet 8 5 inch dispense height with BioCote recessed faucet to protect from cross contamination Leak Detection WL350 Water Treatment Systems are supplied with a Sensor in the Leak Tray that hal...

Page 8: ...quirements are based on the recommendations of the U S Environmental Protection Agency s Task Force Report NSF ANSI 42 Chlorine Taste and Odor Reduction NSF ANSI 53 Lead and Cyst Reduction The Public...

Page 9: ...d Water Temperature Cold Water Temperature Factory Set Point 5 C 41 F Adjustable to 1 1 12 2 C 34 54 F Hot Water Temperature 85 C 185 F Hot Water Manual Reset Overload 105 C 221 F Recommended Incoming...

Page 10: ...13 5 x 14 5 x 41 Weight dry 26 3 kg 58 pounds 30 kg 66 pounds ELECTRICAL SPECIFICATIONS ELECTRICAL SUPPLY 120V 60Hz 15 Amp Service COMPONENT POWER approximate AMP DRAW approximate Heater 504 4 2 Amps...

Page 11: ...ton within 3 seconds For Hot Water Press Hot Water Select Button followed by the Dispensing Button within 3 seconds NOTE Default selection mode is Cold Water Selection will return to default after 3 s...

Page 12: ...tion to Waterlogic for evaluation The form is available at www waterlogic us Supporting documentation must include but is not limited to proof of purchase installation date failure date and supporting...

Page 13: ...nect before removing UV Lamp CAUTION UV LAMPS ARE HAZARDOUS Lamps are considered Hazardous Waste and must be disposed of accordingly Refer to Product MSDS sheet for details 3 Clean the Spiral Quartz S...

Page 14: ...in than out There is a small hole in the side of the tank outlet tube that allows air and water to pass into the vent chamber as it is heated Water in the vent chamber is suctioned back through the ou...

Page 15: ...WL350 Operating Installation and Service Manual Page 15 Revision 8 30 2016 HEATER CIRCUIT HOT TANK WIRING...

Page 16: ...ctive Metal Box on the rear of the hot tank As you look through the condenser coils on the rear of the unit you will see the hot tank located on the right hand side 5 From the front of the Water Treat...

Page 17: ...y depressing the top flap of the Protective Metal Box so it snaps back into its original position on the Hot Tank 8 Replace the Lower Front Panel 9 Plug in the Power Cord 10 Turn on the Red Compressor...

Page 18: ...NK DESCALING The Hot Tank is made from stainless steel Ensure descaling solution is compatible with stainless and always flush the unit completely Dispose in an environmentally safe manner Materials N...

Page 19: ...customer s satisfaction WARNING HOT WATER The WL350 Water Treatment System produces Hot Water up to 86 C 187 F Water above 52 C 125 F can cause severe burns or scalding Hot water should be dispensed...

Page 20: ...WL350 Operating Installation and Service Manual Page 20 Revision 8 30 2016 FIREWALL OUTLET SOLENOID REVERSE FLOW ORIENTATION...

Page 21: ...erature and the range is approximately 7 C 20 F thru the full range of adjustment 7 00 to the 5 00 positions You should be able to turn the screw from the factory set point of 5 C 41 F 12 00 position...

Page 22: ...r or longer period Selecting any button wakes up the WL350 Water Treatment System and turns the heater circuit back on The hot tank will typically take less than 10 minutes to heat the water from ambi...

Page 23: ...t Cold settings On the Energy Saver PCB Move the Jumper on JP9 from Pins 1 and 2 to Pins 2 and 3 Unplug Power Cord and remove Top Cover to access Energy Saver PCB WL350 Water Treatment Systems comes w...

Page 24: ...will determine proper filter type and maintenance schedule WLCP Part No FT 0063 One pre installed One required for NSF 53 and NSF P231 Certification Replacement parts can be obtained from Waterlogic o...

Page 25: ...WL350 Operating Installation and Service Manual Page 25 Revision 8 30 2016 WL350 COUNTER TOP DRAWING AND PARTS LIST Wetted Parts...

Page 26: ...ire EL 5053 Yes 3 1 EL 5010 Fuse 120V 15A 10 3013 Yes 4 EL 5004 Red Compressor Heater Switch 10 3008 Yes 5 ST 8216 Silver Back Panel Counter Top Only 12 8061 No 6 CT 2070 A Cold Tank Thermostat 19 106...

Page 27: ...No 12 PL 1294 Leak Tray Counter Top Only 12 3155 Yes 13 ST 8151 A Bottom Tray Counter Top Only 12 3170 Yes 14 PL 1251 CN Unit Rubber Feet Counter Top Only 12 3150 Yes 15 PU 4010 JG Equal Straight Con...

Page 28: ...3 Silicon Button Key Mat 12 8056 Yes 24 EN 6126 L00 00 Main PCB 12 8355 Yes 25 PL 1357 Firewall PCB Cover 12 8350 Yes 26 PL 1146 A Silver Front Panel for Drip Tray Insert Firewall 12 8345 Yes 27 PL 13...

Page 29: ...0020 L00 00 Spiral Rubber Buffer Included in FU 0007 12 8305 Quartz Spiral Yes 36 FU 0008 A Firewall Mark IV Stainless Assembly No internal components includes FL 0010 Firewall Bracket 12 8330 Yes 36...

Page 30: ...Tank 1 6 Liter 42 gallon 100V 500W Factory Set Point 185 F 85 C 12 5615 Yes 45 1 ST 8290 Thermostat and Overload Metal Cover 12 6900 Yes 45 2 HT 3012 Overload with Manual reset 105 C 221 F 12 1360 Ye...

Page 31: ...1 AK 0014 B Flow Restrictor 1 8 mm hole AK 0014 B Yes 52 PU 4064 Silicon Tube 5 16 for Hot Water 10 7040 Yes 53 PU 4086 JG 1 4 Stopper PI0808S used with Bulkhead Union x John Guest P N PI1208S Counter...

Page 32: ...WL350 Operating Installation and Service Manual Page 32 Revision 8 30 2016 WL350 TOWER LAYOUT DRAWING AND PARTS LIST Wetted Parts...

Page 33: ...se 120V 15A with One Wire EL 5053 Yes 3 1 EL 5010 Fuse 120V 15A 10 3013 Yes 4 EL 5004 Red Compressor Heater Switch 10 3008 Yes 5 CT 2070 A Cold Tank Thermostat 19 1069 Yes 5 1 Lp 0326 l00 00 Cold Ther...

Page 34: ...Wire Tower Only NA No 12 PL 1294 A Leak Tray Tower Only NA No 13 ST 8137 Bottom Tray 12 8004 Yes 14 ST 8167CN Unit Rubber Feet Tower Only 10 3083 Yes 15 PU 4137 JG 3 8 x 1 4 Reducing Fitting PI211208...

Page 35: ...amp Assembly 12 8310 Yes 24 CT 2088 Firewall UV Lamp Rubber 12 8320 Yes 25 CT 2010 CDS Fixing Rubber Silicon 10 3095 Yes 26 FU 0007 Quartz Spiral 12 8305 Yes 27 FW 0020 L00 00 Spiral Rubber Buffer NA...

Page 36: ...CT 2089 UV Sensor UVC Sensor Without Wire CT 2089 Yes 30 3 EL 5141 A Firewall UV Female Wire Connector 12 8335 Yes 31 PL 1351 Hot Water Faucet 12 8370 Yes 32 PL 1146 A Silver Front Panel for Drip Tray...

Page 37: ...3 EN 6131 Energy Saver PCB 20 0075 Yes 44 HT 3041 Hot Tank 1 6 Liter 42 Gallon 100V 500W 12 5615 Yes 44 1 ST 8291 Thermostat and Overload Metal Cover 12 6900 Yes 44 2 HT 3012 Overload with Manual Rese...

Page 38: ...1 4 John Guest P N PE 08 BI 1000F B Purchase from John Guest No 50 AK 0014 B Flow Restrictor 1 8 mm hole AK 0014 B Yes 51 PU 4064 Silicon Tube 5 16 for Hot Water 10 7040 Yes 52 CO 9027 Wire Condenser...

Page 39: ...ervice Manual Page 39 Revision 8 30 2016 WL350 COUNTER TOP WATER FLOW DIAGRAM Cold Tank Filter Solenoid Valves Solenoid Valve Faucet Water Out Filter Dryer Compressor Condenser Hot Tank Water In Auxil...

Page 40: ...vice Manual Page 40 Revision 8 30 2016 Inlet Leak Detection Valve WL350 TOWER WATER FLOW DIAGRAM Water Out Reverse Flow Cold Out Solenoid Valve Filter Water In Solenoid Valves Filter Dryer Condenser C...

Page 41: ...on and Service Manual Page 41 Revision 8 30 2016 WL350 ELECTRICAL DIAGRAM DANGER HIGH VOLTAGE ELECTRICAL HAZARD PCB Printed Circuit Board contains High Voltage Only trained and qualified technicians s...

Page 42: ...Systems and check exterior for damage Sanitizing Sanitize using a Household Bleach 5 25 Sodium Hypochlorite solution or other approved cleaner throughout the cold and sparkling water circuits Follow...

Page 43: ...ilters to perform as represented and to provide the best quality water possible it is essential that filters be replaced periodically The frequency of filter changes depends upon your water quality an...

Page 44: ...utes UV System Functional Test WARNING ULTRAVIOLET RADIATION Protect your skin and eyes against ultraviolet rays Never look directly at an operating UV light Disconnect wiring before removing 14 Remov...

Page 45: ...ressor will shut off Draw a glass of cold water and verify it is has chilled to proper temperature Heater Test 22 Always ensure tanks are full of water before turning on the Heater or the Overload Hig...

Page 46: ...to scalding hot water Disable Cold and Hot Tanks 1 Turn off the Red Heater and Compressor Power Switch O OFF to disable the Heater and Compressor 2 Dispense 2 liters gallon of water through the Hot Ta...

Page 47: ...isable Cold and Hot Tanks 8 Turn off the Red Heater and Compressor Power Switch O OFF to disable the heater and compressor 9 Dispense 2 liters 1 gallon of water through the hot tank to cool the water...

Page 48: ...ure above 37 C 100 F or below 2 C 35 F Install indoors and keep unit away from excessive humidity Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refr...

Page 49: ...dispensing button Hot tank is now full CAUTION NEVER TURN ON HEATER BEFORE FILLING HOT TANK Red Compressor Heater Switch must be in the O OFF position while the hot tank is empty Damage could occur wi...

Page 50: ...has sensed water in the Leak Tray and will shut down inlet solenoid Possible Reason Solution Water is present in the Bottom Tray causing the leak detection to trigger Leak Detection is on the Counter...

Page 51: ...t have adequate dose of UV Check UV System 1 If Ballast Indication Light is Green the system should be operational Ensure UV lamp is on Replace Lamp If lamp is replaced and problem persists replace UV...

Page 52: ...and Service Manual Page 52 Revision 8 30 2016 FAULT CODE No LED Light Possible Reason Solution Power Problem Check for power disruption LED Light is out Check that the PCB LED is operational replace P...

Page 53: ...ter and Compressor Power Switch won t light and the Red LED on the Front won t light Possible Reason Solution Circuit Breaker Check the Circuit Breaker Fuse is Blown Replace Fuse Defective Loose Power...

Page 54: ...CB Replace Front PCB Defective Red Heater Compressor Switch Replace Red Heater Compressor Switch Compressor Runs But Does Not Chill Possible Reason Solution Condenser is dirty Clean the condensing coi...

Page 55: ...position Turn Red Heater Compressor Switch on I ON Compressor Starting Circuit Turn Red Heater Compressor Switch off O OFF Remove the compressor cap on side of the compressor Disconnect the black and...

Page 56: ...Hot Water coming out of Faucet Vent Hole 7 Restricted Flow of Hot Water 8 Hot Water Drip out of Faucet 9 Dispenses Hot and Cold Water at the same time 10 No cold water available 11 Water does not disp...

Page 57: ...put water pressure is critical to the performance of the unit to allow solenoids to open Loose or bad connection on the Front Dispensing PCGB or Solenoid Connector Check that they are connected proper...

Page 58: ...is filling the gap around the push buttons Inspect the push buttons and clean surrounding area Inspect faucet assembly inside the unit and clean as necessary Steady Drip Out of Faucet Possible Reason...

Page 59: ...Tank outlet hole is scaled over Descale Tank See Hot Tank Descaling Instructions that are included further below in this Troubleshooting Section See instructional video on the Partner Area of the Wat...

Page 60: ...the top to the Faucet The Hot Tank Outlet Tube has a Restrictor in its base This ensures the reservoir is always full by allowing more water in than out There is a small hole in the side of the Hot Ta...

Page 61: ...pen the Water Supply Valve Cold Water Solenoid Valve malfunction Inspect the valve components for proper functionality Red Heater Compressor Switch on unit is off If water is dispensing at room temper...

Page 62: ...Compressor Switch on I ON 15 Amp Fuse Blown Replace the 15 Amp Fuse as needed Water is present in the Bottom Tray causing the Leak Detection to trigger Remove the Top Cover and Front Panel Tip the uni...

Page 63: ...tch the hot and cold wires on PCB red and blue connections If water now dispenses from the opposite side this is an indication that there is a PCB problem Replace PCB Solenoid If both the Water Pressu...

Page 64: ...xed to the solenoid stem Remove the stem from the solenoid housing and allow water from the tank to flush out the contaminant s Dispense Buttons Stick Possible Reason Solution Dirt or Foreign material...

Page 65: ...ry Waterlogic tank has an outlet restrictor to ensure the tanks remain full of water and water is controlled as it is released to the faucet The inlet solenoid controls flow into the tanks The tanks w...

Page 66: ...K DESCALING The Hot Tank is made from stainless steel Ensure descaling solution is compatible with stainless and always flush the unit completely Dispose in an environmentally safe manner Materials Ne...

Page 67: ...he customer s satisfaction WARNING HOT WATER The WL350 Water Treatment System produces Hot Water up to 87 C 187 F Water above 52 C 125 F can cause severe burns or scalding Hot water should be dispense...

Page 68: ...quired Refrigerant has run out Run Compressor for at least ten minutes If Condenser is not warm then refill the refrigerant Compressor problem If Compressor is not running repair or replacement is nee...

Page 69: ...ambient water to the 187 F set point Possible Reason Solution Is unit in Energy Star Sleep Mode If no water has been dispensed for 3 or more hours unit goes into sleep mode Dispense hot water wait 5...

Page 70: ...ximately 26 OHM s resistance Hot Tank must be empty if you are checking for continuity Replace Hot Tank as necessary Loose or improperly connected wire s to the Heating Element Hot Tank Visually inspe...

Page 71: ...eriod Selecting any button wakes up the WL350 Water Treatment System and turns the heater circuit back on The hot tank will typically take less than 10 minutes to heat the water from ambient to the 85...

Page 72: ...ctive Metal Box on the rear of the hot tank As you look through the condenser coils on the rear of the unit you will see the hot tank located on the right hand side 5 From the front of the Water Treat...

Page 73: ...y depressing the top flap of the Protective Metal Box so it snaps back into its original position on the Hot Tank 8 Replace the Lower Front Panel 9 Plug in the Power Cord 10 Turn on the Red Compressor...

Reviews: