WL350 Operating, Installation, and Service Manual Page 64 – Revision 8-30-2016
Small Amount of Water Periodically Dispenses from Faucet Automatically
Possible Reason
Solution
Cold or Hot Water solenoid
valve malfunction
Inspect valve components for proper function. Replace as
necessary.
Obstruction in solenoid
housing is preventing proper
sealing of component.
Pre-determine whether water being dispensed is hot or cold.
Isolate the water supply; push the DISPENSE button to release the
line pressure, and remove the coil affixed to the solenoid stem.
Remove the stem from the solenoid housing and allow water from
the tank to flush out the contaminant(s).
Dispense Buttons Stick
Possible Reason
Solution
Dirt or Foreign material is
filling the gap around the
Dispense Buttons.
Inspect the Dispense Buttons and clean surrounding area. Inspect
Faucet Assembly inside the WL350 Water Treatment System and
clean as necessary.
Water Streams at an Angle
Solution
Rotate the Bung (Blue Silicone) and the JG fittings a few degrees.
Water Feed Pressure
Verify the Incoming Feed with a Pressure Regulator. Should be 40-
60 psi (275-414 kPa) – Use Pressure Regulator
The correct input water pressure is critical to the performance of the
unit to allow solenoids to open.