WL350 Operating, Installation, and Service Manual Page 70 – Revision 8-30-2016
Replace components as necessary.
Heating Coil Not
Heating
Turn Power off; Drain hot tank; Use multi-meter to check Heater Element for
approximately 26 OHM’s resistance.
Hot Tank must be empty if you are checking for continuity.
Replace Hot Tank as necessary.
Loose or improperly
connected wire(s) to
the Heating Element
/ Hot Tank.
Visually inspect wire leads gong to the hot tank; confirm proper connections
to the heating elements.
Hot tank life is 3-5 years, depending on usage.
*Typically dealers swap out the Hot Tank at site, take back to the shop to
repair.