MODEL/PART DESIGNATIONS
BRAND NAME
DESCRIPTION
MODEL – PART NUMBER
WL350 Counter Top
Waterlogic WL350 Counter Top - Cold and Hot
12-CHCMFW3
F-2FW-M-HC-TT-CS-INN
WL350 Tower
Waterlogic WL350 Tower - Cold and Hot
12-CHCFW3
F-2FW-FS-HC-TT-CS-INN
SPECIFICATIONS
ITEM
WL350 Counter Top
WL350 Tower
Water Connection
¼” Quick Connect
Cold Water Temperature
Cold Water Temperature – Factory Set Point 5°C (41°F)
Adjustable to 1.1°- 12.2°C (34°
-
54°
F)
Hot Water Temperature
85°C (185°F)
Hot Water Manual Reset
Overload
105°C (221°F)
Recommended Incoming
Feed Pressure
40-60 psi (275-414 kPa) – Use Pressure Regulator
Maximum Service Pressure 100 psi (689 kPa) – Use Pressure Regulator
Rated Service Flow Out
1.89 Liters per Minute (0.5 Gallons per Minute) – Firewall Purification
Environmental Temperature 2°- 37°C (35°- 100°F)
UV Lamp
15 Watts
15 Watts
Heater
500 W
Refrigerant Gas
R134a, 40g, 1.41 ounces
R134a, 65g, 2.29 ounces
R134a Pressures
High (230 psi), Low (90 psi)