WL350
Manual
Page 22 – Revision 11‐21‐2018
ADJUSTING COLD SET POINT
Cold Water Temperature – Factory Set Point is 41°F (5°C) and can be adjusted to 34°F ‐ 54°F (1.1°C to
12.2°C)
The cold set point can be adjusted by accessing the cold
thermostat adjustment screw under the decal at the rear of the
unit.
Remove the red portion of the Cold Tank Temperature label to
access the adjustment screw.
The factory set point is ~41°F and is indicated by the dot on
sheet metal.
Turning the adjustment screw clockwise to lower the set point
temperature.
Do not adjust past the “Max Cold” position at 3:00 position to
avoid freezing the cold tank.
Turning the adjustment screw counter‐clockwise to raise the set
point temperature.
Summary of Contents for WL350
Page 3: ...WL350 Manual Page 15 Revision 11 21 2018 HEATER CIRCUIT HOT TANK WIRING...
Page 8: ...WL350 Manual Page 20 Revision 11 21 2018 FIREWALL OUTLET SOLENOID REVERSE FLOW ORIENTATION...
Page 29: ...WL350 Manual Page 41 Revision 11 21 2018 WL350 COUNTER TOP WATER FLOW DIAGRAM...
Page 30: ...WL350 Manual Page 42 Revision 11 21 2018 WL350 TOWER WATER FLOW DIAGRAM...