WL350
Manual
Page 35 – Revision 11‐21‐2018
WL350 TOWER LAYOUT DRAWING AND PARTS LIST
No
WLCP Part No.
Description
Factory PN
Stocked?
Consumables
1
12‐8310
15W LTFW XTM UV Lamp
CT‐2085‐IA0‐00
Yes
2
FT‐0063‐IL Assy
with FT‐0064
Element
1‐micron 10" Inline CBC Filter
for CTO, Lead, Cyst and Asbestos
Reduction (Carbon Block)
Required for NSF Certification
FT‐0063‐IL Assy
with FT‐0064
Element
Yes
3
12‐5615
Hot Tank 1.6 Liter (.42 gallon)
100V / 500W Factory Set Point
185°F ‐ 85°C
HT‐3041
Yes
Recommended Spare Parts
3.1
12‐6900
Thermostat and Overload Metal
Cover
Recommend stocking 2 each for
every 10 units purchased
ST‐0045‐L00‐00
Yes
3.2
12‐1360
Overload with Manual Reset ‐
105°C (221° F)
Recommend stocking 2 each for
every 10 units purchased
HT‐3012
Yes
3.3
12‐1303
Hot Tank Thermostat ‐ 87°C
(187°F)
Recommend stocking 2 each for
every 10 units purchased
HT‐3013A
Yes
4
TBD
Solenoid Valve 1000mm
(recommend replacing Solenoid
Cushion at same time)
Recommend stocking 2 each for
every 10 units purchased
PU‐0017‐I00‐00
Yes
4.1
CU‐0001
Solenoid Cushion
Recommend stocking 2 each for
every 10 units purchased
CU‐0001
Yes
5
12‐8370
Hot Water Faucet
Recommend stocking 2 each for
every 10 units purchased
PL‐1351
Yes
Summary of Contents for WL350
Page 3: ...WL350 Manual Page 15 Revision 11 21 2018 HEATER CIRCUIT HOT TANK WIRING...
Page 8: ...WL350 Manual Page 20 Revision 11 21 2018 FIREWALL OUTLET SOLENOID REVERSE FLOW ORIENTATION...
Page 29: ...WL350 Manual Page 41 Revision 11 21 2018 WL350 COUNTER TOP WATER FLOW DIAGRAM...
Page 30: ...WL350 Manual Page 42 Revision 11 21 2018 WL350 TOWER WATER FLOW DIAGRAM...