                                                                   Page 44 – Revision 11‐21‐2018 

PRE‐INSTALLATION PROCEDURES 

 

 

      DANGER!

 

 

ELECTRICAL SHOCK HAZARD.  

Only qualified personnel who have read and understand this entire manual should attempt to 
install, or service this unit, failure to do so could result in death or serious injury.  DO NOT plug 
into an electrical supply until specifically instructed.  

 

 

       WARNING!

  

ALWAYS SANITIZE BEFORE USE. 

 Sanitize before use to eliminate any potential microbiological contaminates.     

 

 

Red Compressor/Heater Switch must be in the O=OFF position while the Hot 
Tank is empty.  Damage could occur within one minute and the two Hot Tank 
Overload Devices (High Safety Limit) require manual reset if heater is turned 
on with an empty Hot Tank.  

 

CAUTION!

  

DRIP TRAY DRAIN.

  

If you intend to provide a drip tray drain for your customer, be aware that you 
will be called multiple times per month to service and unclog the tubing 
leading away from the drip tray to drain.  Users will clog the drain with paper 
clips, erasers, napkins, tea bags, gum, and various other intended items.  
Waterlogic recommends you establish a minimum of weekly visits to the 
machine for cleaning of the drip tray drain. 

 

Materials Needed:  

 

Personal Protective Equipment.  Rubber or Nitrile Safety Gloves and Protective Eyewear  

 

Phillips Screwdriver   

 

Temperature Gauge 

 

Water Pitcher or Container to collect water from the faucet 

 

16 Liter (5 gallon) container or drain basin 

 

Sanitizer ‐ Household Bleach (5.25% Sodium Hypochlorite) or Citric Acid Based Cleaner 

 

¼” Plastic Tubing, at least 4 feet in length, and assorted ¼” quick connect fittings 

 

TDS Meter and Test Strips for measuring chlorine – Optional 

 

Sanitizing Cartridge 

 

1.

 

Unpack the 

Waterlogic WL350

 

Water Treatment Systems 

and check exterior for damage.

 

 

  

 

Sanitizing 

 
Sanitize using a Household Bleach (5.25% Sodium Hypochlorite solution) or other approved 
cleaner throughout the cold and sparkling water circuits.  Follow all instructions on the sanitizer 
and flush with fresh water through the faucet until odor and taste is acceptable. 

 

 

Summary of Contents for WL350

Page 1: ...y from the drip tray to drain Users will clog the drain with paper clips erasers napkins tea bags gum and various other intended items Waterlogic recommends you establish a minimum of weekly visits to...

Page 2: ...out the faucet NOTE Container and drain basin will be required to catch the water from the faucet WARNING Use Personal Protective Equipment Gloves and Eye Protection Required The first 7 5 or 11 5 Lit...

Page 3: ...the Sanitizer from the Machine 10 Place a pitcher catch basin or other container under the faucet of the WL350 Water Treatment System 11 Flush the Cold Tank Run several liters gallons of water through...

Page 4: ...een indication LED on front of unit should flash 17 Disconnect power to WL350 Water Treatment System 18 Reconnect UV lamp 19 Connect power to WL350 Water Treatment System Compressor Test 20 Red Heater...

Page 5: ...lding hot water Disable Cold and Hot Tanks 1 Turn off the Red Heater and Compressor Power Switch O OFF to disable the Heater and Compressor 2 Dispense 2 liters gallon of water through the Hot Tank to...

Page 6: ...r and Compressor Power Switch is turned off the heater will not energize and heat the incoming tap water Following this precaution prevents exposing personnel and equipment drains catch basin etc to s...

Page 7: ...blue tubing into the Line Bulkhead fitting at back of the WL350 Water Treatment System to allow water to drain 13 Depress Cold Water Dispense Button until all Cold Water has drained from the WL350 Wa...

Page 8: ...stall indoors and keep unit away from excessive humidity Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refrigeration system condenser to dissipate h...

Page 9: ...Hot tank is now full CAUTION NEVER TURN ON HEATER BEFORE FILLING HOT TANK Red Compressor Heater Switch must be in the O OFF position while the hot tank is empty Damage could occur within one minute a...

Reviews: