WL350
Manual
Page 44 – Revision 11‐21‐2018
PRE‐INSTALLATION PROCEDURES
DANGER!
ELECTRICAL SHOCK HAZARD.
Only qualified personnel who have read and understand this entire manual should attempt to
install, or service this unit, failure to do so could result in death or serious injury. DO NOT plug
into an electrical supply until specifically instructed.
WARNING!
ALWAYS SANITIZE BEFORE USE.
Sanitize before use to eliminate any potential microbiological contaminates.
Red Compressor/Heater Switch must be in the O=OFF position while the Hot
Tank is empty. Damage could occur within one minute and the two Hot Tank
Overload Devices (High Safety Limit) require manual reset if heater is turned
on with an empty Hot Tank.
CAUTION!
DRIP TRAY DRAIN.
If you intend to provide a drip tray drain for your customer, be aware that you
will be called multiple times per month to service and unclog the tubing
leading away from the drip tray to drain. Users will clog the drain with paper
clips, erasers, napkins, tea bags, gum, and various other intended items.
Waterlogic recommends you establish a minimum of weekly visits to the
machine for cleaning of the drip tray drain.
Materials Needed:
Personal Protective Equipment. Rubber or Nitrile Safety Gloves and Protective Eyewear
Phillips Screwdriver
Temperature Gauge
Water Pitcher or Container to collect water from the faucet
16 Liter (5 gallon) container or drain basin
Sanitizer ‐ Household Bleach (5.25% Sodium Hypochlorite) or Citric Acid Based Cleaner
¼” Plastic Tubing, at least 4 feet in length, and assorted ¼” quick connect fittings
TDS Meter and Test Strips for measuring chlorine – Optional
Sanitizing Cartridge
1.
Unpack the
Waterlogic WL350
Water Treatment Systems
and check exterior for damage.
Sanitizing
Sanitize using a Household Bleach (5.25% Sodium Hypochlorite solution) or other approved
cleaner throughout the cold and sparkling water circuits. Follow all instructions on the sanitizer
and flush with fresh water through the faucet until odor and taste is acceptable.