WL350
Manual
Page 46 – Revision 11‐21‐2018
7.
Flush thoroughly per filter manufacturers’ recommendation with fresh water to drain.
8.
Once flushed, install the filters. Following the flow direction on the filter.
NOTE:
Filters should not be flushed prior to 24 hours before installation to limit Microbial
Growth.
9.
Connect
WL350 Water Treatment System
to power.
CAUTION!
NEVER TURN ON HEATER BEFORE FILLING HOT TANK.
Red Heater & Compressor Switch must be in the O=OFF position while the hot
tank is empty. Damage could occur within one minute and the overload (high
limit) will require manual reset if heater is turned on with an empty hot tank.
O=OFF
Flushing the Sanitizer from the Machine
10.
Place a pitcher, catch basin, or other container under the faucet of the
WL350
Water Treatment
System.
11.
Flush the Cold Tank. Run several liters (gallons) of water through the faucet by dispensing cold
water to dilute and remove the sanitizer from the cold circuit. You can use chlorine test strips to
evaluate the water.
12.
Once the sanitizer odor/taste has been flushed out of the cold side of the machine the
sanitization process for the Cold Circuit is now complete.
Fill the Hot Tank
13.
Press the Hot Water Select Button, followed by the main dispensing button to fill the hot tank.
Water will dispense from the faucet once the hot tank is full. Flush until water is clear.
WARNING!
HOT CIRCUIT IS NOT SANITIZED.
Water in the hot circuit is not sanitary until the temperature exceeds 77°C (171
o
F) for at least
5 minutes.