WL350
Manual
Page 76 – Revision 11‐21‐2018
HOT WATER TROUBLESHOOTING INDEX
1.
Hot Water is not Hot 86°± ‐1.5°C (187°± 5°F)
Also includes related instructions for:
Disabling Energy Star Sleep Mode
Resetting the Hot Tank Overload or High Safety Limit
Programming “Changing Hot Water Mode to Ambient Water Mode”
1.
Hot Water is not Hot 86°± ‐1.5°C (187°± 5°F)
The Hot Temperature set point is 85°C (185
°
F) and is controlled by a thermostat on the side of the
Hot Tank.
There is a resettable overload or high limit safety above the thermostat on the side of the Hot Tank
that will trip to prevent damage to the unit if the tank is dry heated (turned on without water in it).
The
WL350 Water Treatment System
is programmable to make Cold / Ambient water – refer to
Disabling Sleep Mode instructions included further below in this Troubleshooting Section.
The
WL350 Water Treatment System
does NOT have Extra Hot capability and the maximum hot
temperature is 87
°
C (189
°
F).
It typically takes 10 minutes for the 500W to heat the 1.6 Liter (0.4 Gallon) of room temperature
(ambient) water to the 85
°
C (185
°
F) set point.
Possible Reason
Solution
No Power
Check that the Red Heater & Compressor switch is on.
Turn Red Heater & Compressor Switch on.
I = ON
Is unit in Energy Star
Sleep Mode?
If no water has been dispensed for 3 or more hours, unit goes into sleep
mode. Dispense hot water, wait 5 minutes, check temperature.
If unit still does not heat proceed to “No power to Heater elements” below.
If unit does heat but you would like to Disable Sleep Mode, refer to the
instructions included further below in this Troubleshooting Section
Hot Tank Overload
Tripped
Overload is a safety
feature to ensure the
tank does not
overheat.
Overload will “click” when pushed. The overload is automatically reset when
pressed.
See Resetting the Hot Tank Overload or High Limit Safety Instructions that
are included further below in this Troubleshooting Section