                                                                   Page 76 – Revision 11‐21‐2018 

HOT WATER TROUBLESHOOTING INDEX 

 

1.

 

Hot Water is not Hot 86°± ‐1.5°C (187°± 5°F)

 

 

Also includes related instructions for: 
 

 

Disabling Energy Star Sleep Mode 

 

Resetting the Hot Tank Overload or High Safety Limit 

 

 

Programming “Changing Hot Water Mode to Ambient Water Mode” 

 

 

1.

 

Hot Water is not Hot 86°± ‐1.5°C (187°± 5°F) 

 

The Hot Temperature set point is 85°C (185

°

F) and is controlled by a thermostat on the side of the 

Hot Tank. 

 

There is a resettable overload or high limit safety above the thermostat on the side of the Hot Tank 
that will trip to prevent damage to the unit if the tank is dry heated (turned on without water in it). 
 
The 

WL350 Water Treatment System 

is programmable to make Cold / Ambient water – refer to 

Disabling Sleep Mode instructions included further below in this Troubleshooting Section.   

 

The 

WL350 Water Treatment System 

does NOT have Extra Hot capability and the maximum hot 

temperature is 87

°

C (189

°

F). 

 

It typically takes 10 minutes for the 500W to heat the 1.6 Liter (0.4 Gallon) of room temperature 
(ambient) water to the 85

°

C (185

°

F) set point.

 

 

Possible Reason 

Solution 

No Power  

Check that the Red Heater & Compressor switch is on. 

 

Turn Red Heater & Compressor Switch on.   

I = ON

 

Is unit in Energy Star 
Sleep Mode? 

If no water has been dispensed for 3 or more hours, unit goes into sleep 
mode.  Dispense hot water, wait 5 minutes, check temperature.   

 

If unit still does not heat proceed to “No power to Heater elements” below.   

 

If unit does heat but you would like to Disable Sleep Mode, refer to the 
instructions included further below in this Troubleshooting Section

 

Hot Tank Overload 
Tripped   
 

Overload is a safety 
feature to ensure the 
tank does not 
overheat. 

Overload will “click” when pushed.  The overload is automatically reset when 
pressed.   
 

See Resetting the Hot Tank Overload or High Limit Safety Instructions that 
are included further below in this Troubleshooting Section

 

 

 