WL350

 Manual 

                                                                   Page 77 – Revision 11‐21‐2018 

Energy Saver PCB 
Relay Board 
Connector Bad 

 
 
Inspect connector for discoloration.   
If there is no discoloration, contact Waterlogic 
Technical Department. 
 
 

Thermostat or 
overload “open” on 
Hot Tank 

Turn Power off.  Check OHM’s resistance across terminals on each 
Thermostat and Overload separately. 

 

Good components will indicate a closed circuit or zero OHM’s on the meter. 

 

Replace components as necessary. 

Loose or improperly 
connected wire(s) to 
the Heating Element 
/ Hot Tank. 

Visually inspect wire leads gong to the hot tank; confirm proper connections 
to the heating elements. 

 

 Hot tank life is 3‐5 years, depending on usage.   

 

*Typically, dealers swap out the Hot Tank at site, take back to the shop to 
repair. 

Heating Coil Not 
Heating  

Turn Power off; Drain hot tank; Use multi‐meter to check Heater Element for 
approximately 26 OHM’s resistance. 

 

Hot Tank must be empty if you are checking for continuity.   

 

Replace Hot Tank as necessary. 

Improper Jumper 
Settings 

 

The unit has been changed to a cold/ambient setting (JP9 has been moved 
from Pin 1 and Pin 2).   
 
Verify that Jumper Pins are located properly for Hot Water Option. 

 
See Changing Hot Water Mode to Ambient Water Instructions included 
further below in this Troubleshooting Section

 

 

 

 