POWER TROUBLESHOOTING INDEX
1. Red Power Switch and Green Heater & Compressor Switch won't light
2. Red Power Switch and Green Heater & Compressor Switch is lit but the Status LED lights
on the Front are not lit
3. Compressor Runs but does Not Chill
4. Compressor is Not Running
1.
Red Power Switch and Green Heater & Compressor
Switch won’t light
Possible Reason
Solution
Circuit Breaker
Check the Circuit Breaker
Fuse is Blown
Replace Fuse. Use 15‐amp Waterlogic Fuse
Defective / Loose Power Cord
Check that Power Cord is properly plugged in. If it is properly
plugged in, use a different power cord to verify. Use only
Waterlogic supplied power cord.
Failed Socket ‐ Power Line
Noise Filter, Electro‐Magnetic
Interference filter (EMI)
Replace Socket ‐ Power Line Noise Filter, Electro‐Magnetic
Interference filter (EMI)
Defective Red Power Switch
Replace Red Power Switch
Defective Green Heater &
Compressor Switch
Replace Green Heater & Compressor Switch