background image

 

WL380

 Manual 

                                                                 Page 40 ‐ Revision:  2‐5‐2018 

 

2.

 

Red Power Switch and Green Heater & Compressor Switch is lit but the Status 
LED lights on the front are not lit 

 
 

Possible Reason 

Solution 

Bad Transformer 

Replace Transformer 

Black Power Connector to the 
PCB is not properly connected 

Properly connect. 

Bad Front PCB  

Replace Front PCB 

Defective Green Heater & 
Compressor Switch 

Replace Green Heater & Compressor Switch 

 

3.

 

Compressor Runs but Does Not Chill 

 
 

Possible Reason 

Solution 

Condenser is dirty 

Clean the condensing coil of any obstructions or dust. 

Reduction of airflow into unit. 

 
Make sure unit is not under minimum ventilation requirements 
(2 to 4 inches of clearance around the unit for heat exchange). 
 

Compressor is running very 
hot (over 150

o

F) 

 
Low or lost refrigerant.   
 
Refrigerant recharge as necessary.  See Specifications for 
refrigerant charge data. 
 

 

 

 