                                                                 Page 41 ‐ Revision:  2‐5‐2018 

 

4.

 

Compressor is Not Running 

 
 

Possible Reason 

Solution 

Red Power and Green Heater 
& Compressor Switch in the  
O = OFF position 

 
 
Turn Green Heater & Compressor Switch on.   

I = ON

 

 
 

Cold Thermostat is Faulty  

 
 
Isolate Power and remove red leads from cold thermostat to check 
continuity.  Thermostat should be closed if sensor is at room 
temperature.  Check for continuity.  Replace thermostat 
 
 

Compressor Starting Circuit  
Faulty or Over Heated 
(tripped) 

 
Turn Green Heater & Compressor Switch off.  

O = OFF. 

 
Remove the compressor cap on side of the compressor;   
 
Disconnect the black and red terminal connectors;  
 
Inspect the starter and overload relay for any defects.   
 
Check with Multi‐Meter to ensure 120V AC is being supplied to the 
compressor starter.  Turn ON Red Power and Green Heater & 
Compressor Switch with meter hooked to red and black 
compressor leads.

 

 

Replace components(s) as needed. 
 

 
 

 

 