OPERATING

 

INSTRUCTIONS

 

 

TO

 

DISPENSE

 

PURIFIED

 

COLD

 

WATER:

 

 

 

Select

 

cold

 

dispense

 

icon

 

until

 

it

 

lights

 

and

 

hold

 

until

 

desired

 

amount

 

is

 

dispensed.

     

 

Release

 

to

 

stop

 

dispense.

   

 

There

 

will

 

be

 

a

 

2

 

second

 

initial

 

delay

 

as

 

Firewall

 

purifies

 

cold

 

water

 

and

 

sanitizes

 

the

 

faucet.

  

Cold

 

will

 

only

 

dispense

 

if

 

Firewall

 

is

 

active

 

to

 

guarantee

 

safest

 

possible

 

water.

  

Cold

 

icon

 

and

 

Firewall

 

Purification

 

Light

 

are

 

disabled

 

if

 

Firewall

 

is

 

inactive.

   

One

 

minute

 

continuous

 

dispense

 

limit.

 

 

 

TO

 

DISPENSE

 

PURIFIED

 

AMBIENT

 

(ROOM

 

TEMPERATURE)

 

WATER:

   

 

Select

 

ambient

 

dispense

 

icon

 

(lower)

 

until

 

it

 

lights.

 

Hold

 

until

 

desired

 

amount

 

is

 

dispensed.

 

 

Release

 

to

 

stop

 

dispense.

   

 

There

 

will

 

be

 

a

 

2

 

second

 

initial

 

delay

 

as

 

Firewall

 

purifies

 

ambient

 

water

 

and

 

sanitizes

 

the

 

faucet.

  

Ambient

 

will

 

only

 

dispense

 

if

 

Firewall

 

is

 

active

 

to

 

guarantee

 

safest

 

possible

 

water.

 

Ambient

 

icon

 

and

 

Firewall

 

Purification

 

Light

 

are

 

disabled

 

if

 

Firewall

 

is

 

inactive.

  

One

 

minute

 

continuous

 

dispense

 

limit.

 

 

    

WARNING!

  

HOT

 

WATER

 

can

 

cause

 

severe

 

burns

 

or

 

scalding.

 

Unit

 

produces

 

Hot

 

Water(

 

189

o

F

 

/

 

87

o

C).

  

Keep

 

unauthorized

 

people

 

and

 

children

 

away

 

from

 

the

 

unit

 

to

 

avoid

 

injury

 

and

 

accidental

 

dispensing.

 

 

TO

 

DISPENSE

 

HOT

 

OR

 

EXTRA

 

HOT

 

WATER:

   

      

 

Select

 

HOT

 

(middle)

 

and

 

AMBIENT

 

(lower)

 

icons

 

together

 

until

 

both

 

light

 

Hold

 

until

 

desired

 

amount

 

of

 

hot

 

is

 

dispensed.

   

 

Release

 

to

 

stop

 

dispense

.

 

 

Icons

 

must

 

be

 

held

 

simultaneously

 

for

 

2

 

second

 

before

 

hot

 

will

 

dispense.

  

This

 

delay

 

is

 

a

 

safeguard

 

to

 

prevent

 

accidental

 

dispense

 

or

 

unauthorized

 

use.

  

 

 
 

NOTE:

  

Hot

 

water

 

may

 

not

 

be

 

immediately

 

available

 

if

 

unit

 

is

 

in

 

energy

 

saver

 

mode.

 

Select

 

any

 

icon

 

to

 

“wake

 

up”

 

or

 

reactivate

 

heater

 

and

 

wait

 

a

 

few

 

minutes

 

for

 

hot

 

water

 

to

 

be

 

produced.

    

 

EXTRA

 

HOT

 

CYCLE

 

(Raise

 

Hot

 

Tank

 

to

 

Elevated

 

Temperature

 

for

 

Tea

 

and

 

Soup):

  

 

Select

 

EXTRA

 

HOT

 

CYCLE

 

icon

 

until

 

it

 

lights

 

and

 

hold

 

for

 

2

 

seconds

 

then

 

release.

   

The

 

icon

 

will

 

flash

 

indicating

 

the

 

extra

 

hot

 

cycle

 

is

 

activated.

  

Icon

 

will

 

continue

 

to

 

flash

 

while

 

water

 

in

 

hot

 

tank

 

heats

 

to

 

extra

 

hot

 

set

 

point

 

(default

 

203

o

F

 

=

 

95

o

C).

   

Flashing

 

will

 

stop

 

once

 

tank

 

has

 

reached

 

extra

 

hot

 

set

 

temperature

 

(typically

 

a

 

minute

 

or

 

two).

  

Extra

 

hot

 

water

 

can

 

now

 

be

 

dispensed

 

per

 

instructions

 

above.

    

 

NOTE:

  

Icons

 

will

 

light

 

when

 

depressed

 

to

 

validate

 

selection.

  

A

 

soft

 

touch

 

is

 

all

 

that

 

is

 

required.

   

A

 

one

 

minute

 

continuous

 

dispense

 

timeout

 

is

 

built

 

in

 

as

 

safeguard.

  

Release

 

and

 

reapply

 

to

 

override.

  

 

 

 

Summary of Contents for WL380

Page 1: ...ved distributors only Do not remove any panel or cover to protect against electrical shock and exposure to UV radiation DANGER ELECTRICAL SHOCK HAZARD Always use a dedicated and properly grounded outl...

Page 2: ...technique to reduce injury risk WARNING STORE AND TRANSPORT UNIT EMPTY ALWAYS SANITIZE BEFORE USE The unit must be completely drained and sealed before storing to avoid stagnation and reduce microbiol...

Page 3: ...Faucet Increased dispense height to accommodate large vessels Intuitive recessed dispense area with smooth cleanable surfaces Removable BioCote Drip Tray Drip tray features a two piece design for eas...

Page 4: ...REWALL PURIFICATION SYSTEM Our breakthrough Firewall technology delivers 99 9999 bacteria free water right at the point of dispense Firewall delivers the safest water possible through a sanitary fauce...

Page 5: ...ard for Microbiological Water Purifiers The Public Health and Safety Organization establishes minimum requirements for health and sanitization characteristics of microbiological water purifiers The re...

Page 6: ...on Rating Input Connections Quick Connect Bulkhead for Potable Water Recommended Water Feed 40 60 psi 275 414 kPa Always Use Pressure Regulator 0 53 gpm 2 LPM Maximum Flow Flow restrictor may be requi...

Page 7: ...Compressor 156 Watts 1 3 Amps Controls 18 Watts 0 15 Amps Firewall UV System 13 Watts 0 11 Amps WL380 TOTAL 687 WATTS 5 7 AMPS WL380 SHIPPING SPECIFICATIONS ITEM WL380 FS Tower Width Depth Height Box...

Page 8: ...p unauthorized people and children away from the unit to avoid injury and accidental dispensing TO DISPENSE HOT OR EXTRA HOT WATER Select HOT middle and AMBIENT lower icons together until both light H...

Page 9: ...action dispensing equipped with back lights to improve user experience Intelligent dispensing limits continuous dispense to 1 minute as added safeguard Large 9 1 4 opening to allow for sports bottle...

Page 10: ...m with supporting documentation to Waterlogic for evaluation The form is available at www waterlogic us Supporting documentation must include but is not limited to proof of purchase installation date...

Reviews: