background image

 

WL380

 Manual 

                                                                 Page 53 ‐ Revision:  2‐5‐2018 

5.

 

Allow descaling solution to remain in the Hot Tank for 15 minutes (length of time may vary 
depending on water conditions). 
 

6.

 

Place a pitcher, catch basin or other container under the faucet of the 

WL380

 

Water Treatment 

System.

 

 

7.

 

Flush the Hot Tank until water runs clear. 

 

8.

 

Once clear Water dispenses from the faucet the Hot Tank has been descaled. Always ensure the 

WL380

 

Water Treatment System

 is performing to the customer’s satisfaction. 

 

 

WARNING!  

HOT WATER.  HOT WATER.  Unit produces Hot Water in excess of 80

o

C (175

o

F).  

Water above 52

o

C (125

o

F) can cause severe burns or scalding.  Keep unauthorized people and 

children away from the unit to avoid accidental dispensing of hot water.   

 

CAUTION

!

  

MUST

 

REPLACE HOT TANK 3‐5 YEARS DEPENDING ON USAGE

.  The Hot Tank and its 

controls must be replaced a minimum of every three to five years to ensure efficient and 
dependable operation.

 

 

 

WARNING!  

REINSTALL ALL PANELS AND COVERS.  

Always reinstall all Panels, Protective Covers, 

and Fasteners after servicing equipment.  Failure to do so could result in severe personal injury 
and will void the certifications and warranty of the equipment

 
 

For additional information and updates visit 

http://techportal.waterlogic.com

 

 

Contact Waterlogic for assistance or help finding an authorized service representative. 

 

 

 

Summary of Contents for WL380

Page 1: ...ming out of Faucet Vent Hole 7 Low Flow of Water 8 Hot Water Drip out of Faucet 9 Dispenses Hot and Cold Water at the same time 10 No cold water available 11 Water does not dispense from unit 12 No Wa...

Page 2: ...Water Pressure to 40 60 psi Loose or bad connection on the Front Dispensing PCB or Solenoid Connector Check that they are connected properly and tightened Solenoid If both the Water Pressure and PCB...

Page 3: ...or Faulty Solenoid Replace Solenoid 4 Steady Drip Out of Faucet Possible Reason Solution Debris in Solenoid Inspect Solenoid for debris and clean out as needed 5 Hot Water or Steam Coming out of both...

Page 4: ...e Reason Solution Determine Flow of Water Rated Flow Rate is 1 89 Liters 0 5 gallons per minute Check flow rate by dispensing into a container to measure for one minute Measure the amount of water tha...

Page 5: ...ucet The Hot Tank Outlet Tube has a Restrictor in its base This ensures the reservoir is always full by allowing more water in than out There is a small hole in the side of the Hot Tank Outlet Tube th...

Page 6: ...oid Replace Solenoid as necessary 10 No Cold Water Available Possible Reason Solution Closed Water Supply Valve Open the Water Supply Valve Cold Water Solenoid Valve malfunction Inspect the valve comp...

Page 7: ...ch on I ON 15 Amp Fuse Blown Replace the 15 Amp Fuse as needed Water is present in the Bottom Tray causing the Leak Detection to trigger Remove the Top Cover and Front Panel Tip the unit slightly to d...

Page 8: ...w dispenses from the opposite side this is an indication that there is a PCB problem Replace PCB Solenoid If both the Water Pressure and PCB have been ruled out then it is the Solenoid Replace Solenoi...

Page 9: ...the tank to flush out the contaminant s 15 Dispense Buttons Stick Possible Reason Solution Dirt or Foreign material is filling the gap around the Dispense Buttons Inspect the Dispense Buttons and clea...

Page 10: ...cet The inlet solenoid controls flow into the tanks The tanks will depressurize once the dispense button is released the inlet solenoid closes A small amount of water will Run On through the faucet as...

Page 11: ...ot Tank is made from stainless steel Ensure descaling solution is compatible with stainless and always flush the unit completely Dispose in an environmentally safe manner Materials Needed Personal Pro...

Page 12: ...er above 52o C 125o F can cause severe burns or scalding Keep unauthorized people and children away from the unit to avoid accidental dispensing of hot water CAUTION MUST REPLACE HOT TANK 3 5 YEARS DE...

Reviews: