WL380
Manual
Page 48 ‐ Revision: 2‐5‐2018
11. Water does not dispense from Unit
Possible Reason
Solution
Closed water supply valve
Open the water supply valve.
The unit is not properly
plugged into electrical outlet
Check electrical outlet connection, or for blown circuit breaker.
Green Heater & Compressor
Switch button on unit is in the
off position
Turn Green Heater & Compressor Switch on.
I = ON
15 Amp Fuse Blown
Replace the 15 Amp Fuse as needed.
Water is present in the Bottom
Tray, causing the Leak
Detection to trigger
Remove the Top Cover and Front Panel. Tip the unit slightly to
drain, dry Bottom Tray completely.
Hot and Cold Solenoid
connections into the Displace
PCB are loose.
Turn power off; unplug the
WL380 Water Treatment System
and
visually inspect Solenoid connections into the Display PCB. Verify
the soldering points on connections are secure into the board.
Remove the PCB to inspect the front of the board.
Exhausted Filter
Replace filters as needed.