14. Small Amount of Water Periodically Dispenses from Faucet Automatically 

 
 

Possible Reason 

Solution 

Cold or Hot Water solenoid 
valve malfunction 

Inspect valve components for proper function.  Replace as 
necessary. 

Obstruction in solenoid 
housing is preventing proper 
sealing of component. 

Pre‐determine whether water being dispensed is hot or cold. 
 
Isolate the water supply; push the DISPENSE button to release the 
line pressure, and remove the coil affixed to the solenoid stem.   
 
Remove the stem from the solenoid housing and allow water from 
the tank to flush out the contaminant(s). 

 

 
15. Dispense Buttons Stick 

 
 

Possible Reason 

Solution 

Dirt or Foreign material is 
filling the gap around the 
Dispense Buttons. 

Inspect the Dispense Buttons and clean surrounding area.  Inspect 
Faucet Assembly inside the 

WL380 Water Treatment System

 and 

clean as necessary. 

 

 
16. Water Streams at an Angle 

 
 

 

Solution 

 

Rotate the Bung (Blue Silicone) and the JG fittings a few degrees. 
 

Water Feed Pressure 

Verify the Incoming Feed with a Pressure Regulator.  Should be 40‐
60 psi (275‐414 kPa) – Use Pressure Regulator

 

Outgoing Flow Rate 

Verify the outgoing Flow Rate.  Should be 1.89 Liters per minute (0.5 
gallons per minute) ‐ Firewall Purification.   
 
Dispense water for one minute – should measure 1.89 Liters (0.5 
gallons) per minute 
 
Change Flow Restrictor if needed. 

Summary of Contents for WL380

Page 1: ...ming out of Faucet Vent Hole 7 Low Flow of Water 8 Hot Water Drip out of Faucet 9 Dispenses Hot and Cold Water at the same time 10 No cold water available 11 Water does not dispense from unit 12 No Wa...

Page 2: ...Water Pressure to 40 60 psi Loose or bad connection on the Front Dispensing PCB or Solenoid Connector Check that they are connected properly and tightened Solenoid If both the Water Pressure and PCB...

Page 3: ...or Faulty Solenoid Replace Solenoid 4 Steady Drip Out of Faucet Possible Reason Solution Debris in Solenoid Inspect Solenoid for debris and clean out as needed 5 Hot Water or Steam Coming out of both...

Page 4: ...e Reason Solution Determine Flow of Water Rated Flow Rate is 1 89 Liters 0 5 gallons per minute Check flow rate by dispensing into a container to measure for one minute Measure the amount of water tha...

Page 5: ...ucet The Hot Tank Outlet Tube has a Restrictor in its base This ensures the reservoir is always full by allowing more water in than out There is a small hole in the side of the Hot Tank Outlet Tube th...

Page 6: ...oid Replace Solenoid as necessary 10 No Cold Water Available Possible Reason Solution Closed Water Supply Valve Open the Water Supply Valve Cold Water Solenoid Valve malfunction Inspect the valve comp...

Page 7: ...ch on I ON 15 Amp Fuse Blown Replace the 15 Amp Fuse as needed Water is present in the Bottom Tray causing the Leak Detection to trigger Remove the Top Cover and Front Panel Tip the unit slightly to d...

Page 8: ...w dispenses from the opposite side this is an indication that there is a PCB problem Replace PCB Solenoid If both the Water Pressure and PCB have been ruled out then it is the Solenoid Replace Solenoi...

Page 9: ...the tank to flush out the contaminant s 15 Dispense Buttons Stick Possible Reason Solution Dirt or Foreign material is filling the gap around the Dispense Buttons Inspect the Dispense Buttons and clea...

Page 10: ...cet The inlet solenoid controls flow into the tanks The tanks will depressurize once the dispense button is released the inlet solenoid closes A small amount of water will Run On through the faucet as...

Page 11: ...ot Tank is made from stainless steel Ensure descaling solution is compatible with stainless and always flush the unit completely Dispose in an environmentally safe manner Materials Needed Personal Pro...

Page 12: ...er above 52o C 125o F can cause severe burns or scalding Keep unauthorized people and children away from the unit to avoid accidental dispensing of hot water CAUTION MUST REPLACE HOT TANK 3 5 YEARS DE...

Reviews: